LISUN’s energy meter test solutions are designed to ensure the accuracy and reliability of electricity consumption measurements, fully aligning with the latest international standards such as IEC 62052-31:2024, IEC 62053-41:2021, and IEC 62052-11:2020. These standards form a comprehensive framework for validating the performance of energy meters under various operational conditions. IEC 62052-31:2024 focuses on electromagnetic compatibility (EMC) testing, ensuring meters operate without interference from external electromagnetic fields. IEC 62053-41:2021 sets accuracy requirements for static DC energy meters, specifying error limits under both steady and dynamic conditions. IEC 62052-11:2020 complements them by defining environmental conditions and performance testing procedures, including temperature, humidity, and vibration. performance expectations.
LISUN’s energy meter test solutions covers all key testing items involved in the above standards and is equipped with a complete set of professional testing equipment, which can meet multi-dimensional needs such as atmospheric conditions and temperature-humidity tests, test probe contact tests, insulation and impedance measurement, creepage distance detection, pulse voltage and surge tests, mechanical strength (impact, vibration, spring hammer) tests, flame retardancy (glow wire, combustion, heat resistance) tests, dust and waterproof tests, as well as electromagnetic compatibility (fast transient pulses, radio frequency electromagnetic fields, electrostatic discharge, etc.) tests. Through one-stop testing support, it helps manufacturers and laboratories ensure that energy meters comply with national standards and guarantees their stability and accuracy in practical applications.
Energy Meter Test Solutions
Standard:
LISUN supplies the fully test solutions for the following IEC 62052-31:2024, please see the below excel table:
IEC 62052-31:2024 Clause and Subject | LISUN MODEL |
4.3.1 Atmospheric conditions | GDJS-015B |
10.4 Temperature test | |
6.2.2 Test probe B&test probe 11 | SMT-PB&SMT-1150 |
6.4.3 Basic insulation | WB2681A |
6.4.4 Impedance | LS90 |
6.7.2.3 Creepage distances | CK-1 |
6.9.3.1 Impulse voltage test | SUG255 |
6.9.3.2 Surge test | SG61000-5 |
6.9.3.4 DC voltage test | DC3005 |
8.2 Spring hammer test | IK01-07 |
9.3.2.1 glow-wire test | ZRS-3H |
9.3.2.3 vertical burning test | HVR-LS |
10.5 Resistance to heat | ZBP-T |
GW-500 | |
11 Protection against penetration of dust and water | SC-015 |
JL-X |
LISUN supplies the fully test solutions for the following IEC 62053-41:2021, please see the below excel table:
IEC 62053-41:2021 Clause and Subject | LISUN MODEL |
Table 5 Radiated, radio-frequency. electromagnetic field immunity test – test with current | GTEM-2 |
Table 5 Electrical fast transient/burst immunity test | EFT61000-4 |
Table 5 Immunity to conducted disturbances, induced by radio-frequency fields | RFCI61000-6 |
Table 5 Power frequency magnetic field immunity test | PFM61000-8A |
Table 5 Dry Heat Test&Cold Test&Damp heat cyclic test | GDJS-015B |
9.2 Conducted differential mode current disturbances for DC meters | LFCI61000-1619 |
LISUN supplies the fully test solutions for the following IEC 62052-11:2020, please see the below excel table:
IEC 62052-11:2020 Clause and Subject | LISUN MODEL |
5.2.1 Shock test | DT-60KG |
5.2.2 Vibration test | LVD-100KG |
8.3.3&8.3.4 Dry heat test&Cold test | GDJS-015B |
8.3.6 Protection against solar radiation | XD-500LS |
9.3.2 Voltage dips and short interruptions | CSS61000-11 |
9.3.3 Electrostatic discharge immunity test | ESD61000-2 |
9.3.4 Radiated, radio-frequency, electromagnetic field immunity test – test without current | GTEM-2 |
9.3.5 Radiated, radio-frequency, electromagnetic field immunity test – test with current | |
9.3.6 Electrical fast transient/burst immunity test | EFT61000-4 |
9.3.7 Immunity to conducted disturbances, induced by radio-frequency fields | RFCI61000-6 |
9.3.8 Test for immunity to conducted, differential mode disturbances and signalling | LFCI61000-1619 |
in the frequency range 2 kHz to 150 kHz at AC power ports | |
9.3.9 Surge immunity test | SG61000-5 |
9.3.10 Ring wave immunity test | RWG61000-12 |
9.3.11 Damped oscillatory wave immunity test | DOW61000-18 |
9.3.13 Power frequency magnetic field immunity test | PFM61000-8A |