+8618117273997weixin
EnglishEnglish
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語

REQUEST A QUOTE

=

Programmable Withstanding Voltage & Insulation Tester

Product No: LS9923

  • Specifications
  • Videos
  • Downloads
  • Applications
  • Standards
  • Installations
  • Tech Articles
  • The LS9923 Programmable Withstanding Voltage & Insulation Tester is an integrated testing device developed by LISUN specifically for the safety inspection of electrical products. It centrally integrates two key functions: AC/DC withstand voltage testing and insulation resistance testing. It can accurately evaluate the insulation performance and breakdown resistance of electronic products under high-voltage conditions, and is widely suitable for compliance testing needs of electrical products in multiple fields such as household, industrial, and medical.

    The LS9923 adopts a high-precision voltage sampling module and a fast overcurrent protection circuit. Its output voltage range covers AC/DC 0~5.00KV, and the overcurrent cutoff speed is fast (millisecond-level response), which can effectively avoid irreversible damage to the tested equipment caused by continuous high-voltage breakdown. Meanwhile, it is equipped with convenient functions such as remote control rod operation, acousto-optic alarm, and automatic test time control. The operation interface is simple and intuitive, making it suitable for both batch testing scenarios where production line workers can quickly get started, and refined testing needs during the R&D phase in laboratories. It is an ideal insulation and withstand voltage testing tool that balances safety, accuracy, and ease of use.

    Reference Standards:

    Standards No. Standards Name
    IEC/EN 60335-1 Household and similar electrical appliances – Safety – Part 1: General requirements
    IEC 60598-1 Luminaires – Part 1: General requirements and tests
    UL 60335-1 Standard for Safety of Household and Similar Electrical Appliances – Part 1: General Requirements
    IEC/EN 60950-1 Information technology equipment – Safety – Part 1: General requirements
    IEC 60601-1 Medical electrical equipment – Part 1: General requirements for basic safety and essential performance
    GB 4706.1-2024 家用和类似用途电器的安全 第 1 部分:通用要求
    GB 7000.1-2023 灯具 第 1 部分:一般要求与试验
    GB 4943.1-2022 信息技术设备 安全 第 1 部分:通用要求
    GB 9706.1-2020 医用电气设备 第 1 部分:安全通用要求
    GB 19212.1-2021 电力变压器、电源装置和类似产品的安全 第 1 部分:通用要求和试验

    Note: Different standards have slightly different requirements for Programmable Withstanding Voltage & Insulation Tester. We recommend that you confirm with LISUN engineers which standards each LISUN Programmable Withstanding Voltage & Insulation Tester model meets in order to accurately match your testing needs.

    Specifications:

    Withstanding Voltage Output Voltage Range AC/DC 0~5.00KV
    Output Voltage Accuracy ± (3%+3bits)
    Breakdown Current Range AC: Max 20mA; DC: Max 10mA
    Test Time 0~999.9s
    Output Frequency 50Hz/60Hz
     Insulation Resistance Output Voltage Range DC 0~1.00KV
    Output Voltage Accuracy  ± (2%+3bits)
    Insulation Resistance Range 1.0~2000MΩ
    Insulation Resistance Accuracy ± (5%+3bits) <100MΩ and ± (10%+5bits) >100MΩ
    Test Time 0~999.9s

    Applications:
    • Household Appliance Industry: Withstand voltage tests for power cords and enclosures of products such as rice cookers, washing machines, and electric irons, compliant with IEC 60335-1 (GB 4706.1), to prevent electric leakage risks.
    • Lighting Industry: Insulation resistance tests for LED ceiling lights, outdoor floodlights, and stage lighting fixtures (e.g., insulation between lamp holders and enclosures), meeting IEC 60598-1 (GB 7000.1).
    • Electronic Components Industry: Withstand voltage breakdown tests for components like capacitors, transformers, and relays, ensuring no breakdown occurs under rated voltage.
    • Wire and Cable Industry: Withstand voltage tests for insulation layers of power cords and signal cables to verify their high-voltage resistance, compliant with IEC 60204-1 (GB/T 24344).
    • Medical Equipment Industry: Insulation resistance tests for small medical diagnostic instruments and physiotherapy devices, meeting the safety requirements for medical equipment specified in IEC 60601-1 (GB 9706.1).
    • Industrial Machinery Industry: Withstand voltage tests for industrial electrical equipment such as machine tools and motor control boxes, compatible with GB/T 24344, to ensure electrical safety in industrial

    Tags:
  • Calibrate Certificate

    Standards

  • HID Lamp Test Solutions

    For the HID Lamp design and manufactory, LISUN can supply a full quality control test solution.

    Fluorescent Lamp Test Solutions

    For the Fluorescent Lamp design and manufactory, LISUN can supply a full quality control test...

    CFL Lamp Test Solutions

    For the CFL (Compact Fluorescent Lamp) design and manufactory, LISUN can supply a full quality...

    LED Driver Test Solutions

    The LED Driver is the key factor for the LED luminaires. Its quality decide the life of the LED...

  • UL 1561:2023 sets safety specifications for dry-type general purpose and power transformers. Its Clause 23 temperature test follows ANSI/IEEE C57.12.91. K-factor rated transformers must be subjected...
    UL 817:2025 (13th Edition) is the ANSI/UL safety standard for cord sets and power‑supply cords rated up to 600 V, used in non‑hazardous indoor locations per NFPA 70. It covers molded/assembled plugs,...
    UL 217:2024 (10th Edition) is the latest ANSI/UL safety standard governing electrically operated single/multiple‑station smoke alarms and portable travel alarms for indoor open‑area protection,...
    UL 2075:2021, published by Underwriters Laboratories (UL) and updated in August 2021, is a safety standard covering fixed, portable, and transportable toxic and combustible gas/vapor detectors and...
    IEC 60335-2-6:2024 is a safety standard focusing on stationary electric cooking appliances for household and similar use, including cooking ranges, hobs (e.g., induction cooktops), ovens (pyrolytic,...
    IEC 60099-4:2014 is an international standard specifying technical requirements, test methods, and performance criteria for gapless metal-oxide surge arresters (MOSAs) used in alternating current...
    This Standard UL 1598: 2012 is issued jointly by the Association of Standardization and Certification (ANCE), the Canadian Standards Association (CSA),and Underwriters Laboratories Inc. (UL).
    The purpose of this document IEC 60947-1:2020 is to harmonize as far as practicable all rules and requirements of a general nature applicable to low-voltage switchgear and controlgear in order to...
    IEC 60335-2-9Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances need to use LISUN goniophotometer,...
    IEC 60335-2-5Household and similar electrical appliances - Safety - Part 2-5: Particular requirements for dishwashers need to use LISUN goniophotometer, integrating sphere and spectroradiometer...
  • Turkey-Install the LSG-1800BCCD High Precision Rotation Luminaire Goniophotometer by watching the vedio

    15 Jan, 2021

    This customer is a relatively well-known manufacturer of various indoor and outdoor lamps in Istanbul of Turkey. It’s...

  • Test equipment for electrical safety and function

    20 Jul, 2022

    With the rapid development of contemporary science and technology, measuring instruments for...

    Electrical Safety Performance Test

    17 Sep, 2014

    The equipment for electrical safety performance test is in rapid development of modern science...

    Programmable Lighting Safety Tester

    07 May, 2012

    According to IEC60598 standards, the lighting fixtures must be passed the safety test on AC Voltage...

    Automatic Electrical Safety System and the notes when you are testing

    31 Aug, 2020

    Equipment introduction: Automatic Electrical Safety System can test for Withstand Voltage (AC/DC),...

    Precision Operation of Dielectric Strength Testeing: Ensuring Electrical Product Safety and Reliability

    03 Sep, 2024

    Dielectric strength testing assesses the ability of electrical devices, insulation materials, and...

    Analysis of IS 16102-1:2026 Standard Update and LISUN’s Product Adaptation Plan

    26 Apr, 2026

    On February 24, 2026, the Bureau of Indian Standards (BIS) officially released the revised safety...

    LISUN LS9923 Programmable Withstanding Voltage And Insulation Tester – After-sales Frequently Asked Questions (FAQ)

    10 Nov, 2022

    LS9923 programmable withstand voltage & insulation tester use to do electricial products safety...

    LS9923 Withstanding voltage and Insulation Test System is Designed According to IEC60335-1-General Requirements

    11 May, 2021

    The full name of IEC60335-1 is Household and similar electrical appliances-Safety. This part of...

    Why should choose the programmable withstand voltage tester

    18 Jan, 2022

    At present, the withstand voltage tester seen on the market adopts the GB4706 (equivalent to...

    Analysis of IS 16102-2:2026 Standard Update and LISUN’s Adaptation Solutions

    27 Apr, 2026

    In 2026, the Bureau of Indian Standards (BIS) completed and issued the revised standard IS...