IEC 60502-1:2021 has been prepared by IEC technical committee 20: Electric cables. It is an International Standard.
This third edition cancels and replaces the second edition published in 2004 and Amendment1:2009. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) references to IEC 60811 (all parts) have been updated and mechanical testing requirements specific to halogen free low-smoke oversheath of material type STg have been considered;
b) the use of the types of sheathing material to be used is now clearly defined;
c) the applicability of cables for use in DC systems is now included in the scope;
d) items which were earlier marked as “under consideration* were studied either for an appropriate solution if found available, or for removal for the time being.
Wires Cables Test Solution
LISUN supplies the fully test solutions for the following IEC 60502-1:2021, please see the below excel table:
IEC 60502-1:2021 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 kV (Um = 1,2 kV) UP TO 30 kV (Um = 36 kV)- Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) |
LISUN MODEL |
Clause 17.3 Insulation resistance measurement at maximum conductor temperature | WB2681A |
Clause 18.8 Pressure test at high temperature on insulation and non-metallic sheaths | GNGPL-3610-2PA |
Clause 18.9 Test on PVC insulation and sheaths and halogen free sheaths at low temperatures | DWC-1 |
Clause 18.10 Test for resistance of PVC insulation and sheaths to cracking (heat shock test) | LS-B38 |
Clause 18.11 Ozone resistance test for EPR and HEPR insulation | OTC-150A |
Clause 18.15 Fire tests | RSB-WC |
Clause 18.19 Determination of hardness of HEPR insulation | LS-B04 |
Table 15 Tensile Strength | PULL-2000KG |