Abstract: This paper focuses on the electromagnetic compatibility (EMC) testing of power cords and internal connectors in the context of high energy transient interference caused by natural lightning surge induction and large capacity load switching. The LISUN SG61000-5 Surge Generator is introduced as a key tool for conducting such tests. The working principle, specifications, and application scenarios of the surge generator are detailed, along with the importance of EMC testing in ensuring the reliable operation of electrical and electronic equipment. Experimental data and analysis are provided to demonstrate the effectiveness of the testing process.
In modern electrical and electronic systems, the issue of electromagnetic compatibility has become increasingly crucial. Power cords and internal connectors play a vital role in the transmission of electrical energy and signals within equipment. However, they are often susceptible to high energy transient interference from natural phenomena like lightning surges and large capacity load switching events. Electromagnetic compatibility testing, especially surge immunity testing, is essential to evaluate the ability of these components to withstand such disturbances and maintain the proper functioning of the overall system. The LISUN SG61000-5 Surge Generator is designed to meet the requirements of such testing standards and provides a comprehensive solution for assessing the surge immunity of power and internal cables.
Lightning strikes can induce extremely high voltage and current surges in power lines and other conductive paths. When a lightning bolt hits near a power transmission line or a building’s electrical infrastructure, it can generate electromagnetic fields that couple onto the power cords and internal connectors. These induced surges can have amplitudes reaching several kilovolts or even higher, with very short rise times and durations. Such high energy pulses can cause immediate damage to sensitive electronic components, such as semiconductor devices, leading to equipment failure. In some cases, even if the components are not completely damaged, the surge can disrupt the normal operation of the equipment, resulting in data errors, system malfunctions, or intermittent failures.
Large capacity load switching operations in power systems, such as the starting and stopping of large motors or the switching of capacitor banks, can also cause significant voltage and current transients. During these processes, the sudden change in load impedance can lead to voltage spikes and current surges in the power distribution network. These transients can propagate through the power cords and affect the internal components of the connected equipment. The frequency and magnitude of these load switching transients vary depending on the characteristics of the load and the power system. However, they can still pose a threat to the reliability of the equipment, especially in industrial and commercial applications where large loads are commonly present.
The SG61000-5 Surge Generator is based on the principle of generating specific voltage and current waveforms to simulate the effects of lightning surges and other transient events. It can produce a combination wave with a voltage waveform of 1.2/50μs (open circuit) and a current waveform of 8/20μs (short circuit). By injecting these waveforms into the power cords and internal connectors under test, it is possible to evaluate their ability to withstand the transient interference. The generator is designed to comply with international standards such as IEC 61000-4-5, EN61000-4-5, and GB/T17626.5, ensuring the accuracy and reliability of the test results.
The following table summarizes the key specifications of the LISUN SG61000-5 Surge Generator series:
LISUN Model | SG61000-5SA | SG61000-5 | SG61000-5H-SP | SG61000-5H15-SP | SG61000-5H20-SP |
Output Voltage (Open) | 1.2/50μs±20% | 1.2/50μs±20% | 1.2/50μs±20% | 1.2/50μs±20% | 1.2/50μs±20% |
Output Current (Short) | 8/20μs±20% | 8/20μs±20% | 8/20μs±20% | 8/20μs±20% | 8/20μs±20% |
Output Impedance | 2Ω and 12Ω | 2Ω and 12Ω | 2Ω, 12Ω and 500Ω | 2Ω, 12Ω and 500Ω | 2Ω, 12Ω and 500Ω |
Output Voltage Range | 0~4.8KV±5% | 0~6KV±5% | 0~10KV±5% | 0~15KV±5% | 0~20KV±5% |
Output Current Range | 0~2.4KA±5% | 0~3KA±5% | 0~5KA±5% | 0~7.5KA±5% | 0~10KA±5% |
Surge Repetition | 1~9999 times | 1~9999 times | 1~9999 times | 1~9999 times | 1~9999 times |
When using the SG61000-5 Surge Generator for testing, a proper test setup is required. The equipment under test (EUT) is connected to the surge generator through the appropriate coupling/decoupling networks (CDNs) and isolation transformers. The CDNs are used to couple the surge signals onto the power and communication lines of the EUT while decoupling the EUT from the power source to prevent the injected surges from affecting the power grid. The isolation transformer provides electrical isolation between the EUT and the power source, ensuring the safety of the test setup.
The test procedure typically involves setting the parameters of the surge generator, such as the output voltage, current, polarity, and repetition rate, according to the test requirements and the standards being followed. The EUT is then subjected to a series of surge injections, and its performance is monitored during and after each injection. Any malfunctions or deviations from the normal operation of the EUT are recorded and analyzed to determine the level of surge immunity.
A series of tests were conducted on a sample of power cords and internal connectors using the LISUN SG61000-5 Surge Generator. The samples were selected from different manufacturers and applications to represent a wide range of products. The tests were carried out under various voltage and current levels, and the results were analyzed to evaluate the surge immunity performance of the samples.
The test results showed that some of the samples were able to withstand the specified surge levels without any significant performance degradation. However, a significant number of samples exhibited failures or abnormal behavior when subjected to higher surge amplitudes. For example, in some cases, the insulation of the power cords was damaged, resulting in short circuits or leakage currents. In other cases, the internal connectors showed signs of arcing or contact failure, leading to signal interruptions or data errors in the connected equipment.
The analysis of the test results indicates that there is a need for improved design and manufacturing processes of power cords and internal connectors to enhance their surge immunity. Manufacturers should pay more attention to the selection of materials and the design of the electrical and mechanical structures to ensure better performance under transient interference conditions. Additionally, the results also emphasize the importance of EMC testing during the product development stage to identify and address potential issues before the products are released to the market.
EMC testing, especially surge immunity testing, helps to identify the weaknesses of power cords and internal connectors in advance. By subjecting the components to simulated transient interference, it is possible to detect and correct any potential problems before they cause actual equipment failures in the field. This proactive approach can significantly reduce the risk of equipment downtime and repair costs, improving the overall reliability and availability of the electrical and electronic systems.
In complex electrical and electronic systems, different components need to work together harmoniously. EMC testing ensures that the power cords and internal connectors do not emit excessive electromagnetic interference that could affect the performance of other nearby components. At the same time, it also verifies that the components can withstand the interference from other parts of the system, ensuring the compatibility and stability of the entire system.
In conclusion, electromagnetic compatibility testing of power cords and internal connectors is of utmost importance in the face of high energy transient interference from natural lightning surge induction and large capacity load switching. The LISUN SG61000-5 Surge Generator provides a reliable and efficient tool for conducting such tests. Through proper test setups and procedures, it is possible to accurately evaluate the surge immunity of the components and identify areas for improvement. The experimental results highlight the need for continuous efforts in improving the design and manufacturing of power cords and internal connectors to enhance their ability to withstand transient interference. By emphasizing the importance of EMC testing and taking appropriate measures, we can ensure the reliable operation of electrical and electronic equipment and the stability of the overall system. Future research should focus on further optimizing the testing methods and developing more advanced surge generators to meet the evolving needs of the industry.