+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
27 Sep, 2023 290 Views Author: Raza Rabbani

Analyzing the Influence of Environmental Factors on High Precision Spectroradiometer Integrating Sphere Measurements

Introduction
The capabilities of high precision spectroradiometer integrating sphere systems for measuring spectra and characterizing sources are quite helpful. However, in order to produce reliable and consistent results, it is very necessary to take into consideration the influence that environmental factors have on these measurements.

In this research, the effect of environmental factors on the precision of measurements obtained from an integrating sphere using a spectroradiometer with a high degree of precision is investigated. It is necessary for researchers, engineers, and manufacturers to understand and minimize these effects in order to gather reliable and consistent spectrum data. This will allow them to make informed judgements regarding lighting design, colorimetry, and photometry, which are all important aspects of lighting design.

The reliability of the measurements taken by professionals may be improved, and the impacts of environmental challenges can be mitigated, to result in an overall improvement in the performance and quality of lighting systems.

Temperature Effects
Readings from spectroradiometer integrating spheres of high accuracy are temperature-dependent, which is significant since temperature is an element of the environment. The following is a list of important factors connected to temperature:

  1. Thermal Stability: Temperature fluctuations might have an effect on the measurements of the spectrum. During the course of the measurements, it is essential to maintain a consistent temperature for the spectroradiometer, the integrating sphere, and the light source. The use of thermal insulation and temperature control devices has the potential to result in increased measurement accuracy.
  2. Thermal Equilibrium: Before any measurements are taken, it is critical to guarantee that the spectroradiometer, the integrating sphere, and the light source are all at the temperatures at which they are designed to function. This equilibrium increases the consistency and dependability of the results by mitigating the impact of temperature gradients and bringing the response of the system into a state of stability.
  3. Thermal Drift: It is well known that the spectrum response of a number of different spectroradiometers will “drift” as the temperature varies. Methods of temperature compensation, such as calibration correction factors, may be used to reduce the impact of this effect and improve measurement accuracy via the correction of spectrum drift.

Humidity Effects
Another environmental component that might affect readings from an integrating sphere in a spectroradiometer is humidity. The following factors need to be considered:

  1. Optical Surface Contamination: When there is a high level of relative humidity, it is possible for water droplets to condense and settle on the optical surfaces of the spectroradiometer and the integrating sphere. It’s possible that the transmission and reflection qualities of the spectrum may be altered by this pollution, which will lead to erroneous readings. Regular cleaning and maintenance of optical surfaces is required in order to decrease the effects of these impacts.
  2. Humidity Control: Always ensuring that the humidity level is properly controlled in the environment is essential for obtaining accurate measurements. By using a humidity-controlled chamber or desiccant devices, one is able to lessen the impact that moisture has on the measurement instrument.
  3. Spectral Absorption: Certain materials, such as optical filters and diffusers, may have their spectrum absorption qualities altered when exposed to high levels of humidity. By being aware of and making adjustments for these effects during the calibration or measurement process, accurate collection of spectral data may be ensured.

Ambient Light Interference
Measurements made using a spectroradiometer’s integrating sphere may be affected by interference from outside sources and the quality of the ambient light. Keep in mind the following details:

  1. Stray Light: If the measurement is contaminated by undesired stray light from external sources, then it is possible that inaccurate spectral data will be produced. It is possible to stop undesired light from accessing the spectroradiometer by using baffles or light traps.
  2. Spectral Contamination: There is a possibility that the existence of ambient light may add additional spectral components to the information that is being gathered. When collecting measurements, the ideal environment would be one that was controlled and had a low level of ambient light interference. This would allow the spectrum contribution of the light source being investigated to be separated. For this reason, a darkroom or another form of chamber that is not affected by light is used.
  3. Spectral Correction: In the event that it is not possible to eliminate interference from surrounding light, it is still possible, via the use of spectral correction methods, to disentangle the contribution of the light source’s spectrum from that of the light in the environment. One method that may be utilized to achieve this objective is to derive the absence of the light from the spectral data. This would be an example of inference.

Calibration and Compensation Techniques
When measurements from a high-precision spectroradiometer integrating sphere are affected by external factors, it is possible to lessen their effect by using calibration and compensating techniques:

  1. Temperature Calibration: By calibrating the spectroradiometer’s thermal sensitivity, one may get an accurate correction for the spectrum drift that is caused by temperature changes. During this step of the calibration process, the temperature sensitivity of the instrument is assessed, and correction factors are added to the data that has been acquired.
  2. Humidity Calibration: Utilizing calibration procedures is another method that may be used to account for the impact that humidity has on spectral measurements. It is required to describe the spectroradiometer’s response at varied humidity levels in order to account for humidity-induced errors. This is done so that the humidity-induced inaccuracies may be accounted for.
  3. Ambient Light Compensation: Through the use of reference techniques, it is possible to lessen the interference caused by ambient light. To do this, first the measurements are taken with the light source turned off, and then the contribution of the surrounding light is subtracted from those results.

Environmental Control and Standardization
Establishing a controlled measuring environment is very necessary if one want to minimize the influence that external factors have on the outcomes of a measurement. Take into consideration the procedures that are listed below:

  1. Temperature Control: One way to guarantee a constant temperature during measurements is to use a temperature-controlled chamber or enclosure. This lessens fluctuations caused by temperature and improves the precision of measurements.
  2. Humidity Control: It may be possible to utilize humidity-controlled chambers or desiccant devices in order to reduce the impact that moisture has on the results of measurements.
  3. Light Isolation: When building the measurement setup, it is essential that the amount of interference caused by ambient light be reduced to a minimum. Through the use of light-tight chambers, baffles, and shields, it is possible to prevent spectrum pollution and the blocking of external light sources.
  4. Standardization: If the measurements of the spectroradiometer integrating sphere are carried out in accordance with the established standards and guidelines, then it is possible to achieve results that are consistent and comparable across a number of different systems and laboratories. When standardized methods, calibration procedures, and measurement protocols are employed, spectral data is increased in its reliability and its ability to be repeated. You can get the best integrating spheres from LISUN.

Conclusion
High precision spectroradiometer integrating sphere readings are susceptible to environmental influences. Accurate and trustworthy spectrum data cannot be obtained without first understanding and then minimizing the impacts of temperature, humidity, and ambient light.

Professionals may reduce the possibility of mistake and improve the precision of their measurements via the use of temperature and humidity control methods, calibration and compensating procedures, and the establishment of a uniform measuring environment.

The results of these efforts include more informed choices in lighting design, colorimetry, and photometry. They also increase our knowledge of light sources. Researchers, engineers, and manufacturers can assure reliable spectrum measurements in their quest to improve lighting technologies and applications if they first recognize and then manage the impact of environmental conditions.

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are GoniophotometerIntegrating SphereSpectroradiometerSurge GeneratorESD Simulator GunsEMI ReceiverEMC Test EquipmentElectrical Safety TesterEnvironmental ChamberTemperature ChamberClimate ChamberThermal ChamberSalt Spray TestDust Test ChamberWaterproof TestRoHS Test (EDXRF)Glow Wire Test and Needle Flame Test.

Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp:+8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp:+8618117273997

Tags:

Leave a Message

Your email address will not be published. Required fields are marked *

=