LED Lamps Aging and Life Test
26 Mar, 2018 4056 Author: root

LED Lamps Aging and Life Test

Many customers need aging LED lamps, but do not have a clear concept of aging test and life test. Aging test usually use aging test racks. What is aging test rack? Aging rack is dedicated to simulate the products in real conditions involved in the use of various factors on the aging of the product conditions to strengthen the process of the corresponding conditions. Why we need aging test? Electro...

Read More
Surge generator: IEC 61000-4-5-2014 Surge Immunity Test
25 Mar, 2018 3845 Author: root

Surge generator: IEC 61000-4-5-2014 Surge Immunity Test

The International Electrotechnical Commission (IEC) has published IEC 61000-4-5:2014, “Electromagnetic Compatibility (EMC) – Part 4-5: Testing and Measurement Techniques – Surge Immunity Test.” “IEC 61000-4-5:2014 relates to the immunity requirements, test methods and range of recommended test levels for equipment with regard to unidirectional surges caused by over-voltages from switch...

Read More
What is the difference between IEC/ EN 60825-1 and IEC/ EN 62471?
02 Feb, 2018 7874 Author: root

What is the difference between IEC/ EN 60825-1 and IEC/ EN 62471?

IEC 60825-1: 2007 is a standard issued by the European Union, applicable to safety of laser products emitting laser radiation in the wavelength range 180 nm to 1 mm. Its scope of application would be only applied to LASER products after September 2010, and LED lighting products are no longer covered by the latest version of IEC / EN 60825-1, but need to be assessed in accordance with IEC / EN 6247...

Read More
LED light spectrum related knowledge
26 Dec, 2017 7760 Author: root

LED light spectrum related knowledge

Spectrum is the relative distribution of wavelength and light intensity. The spectrum of LED is generally monochromatic LED, such as blue LED with a peak wavelength of 470nm, with shorter peak wavelength ultraviolet area and with longer peak wavelength green areas as the determination limitation of light intensity. And the spectrum of incandescent lamp, its luminous intensity is widely distributed...

Read More
New Product – LMS-6000 Portable CCD Spectroradiometer
24 Nov, 2017 4373 Author: root

New Product – LMS-6000 Portable CCD Spectroradiometer

In order to meet the demands of the lighting market for handle spectrometer, Lisun launches LMS-6000 Portable CCD Spectrometer recently. Compare with Lisun CHROMA-2 Pocket Chroma Meter, LMS-6000 is lighter and easy to carry. Of course, the price is more competitive. LMS-6000 can be inserted SD card to store data, which is easy to use. Let us introduce LMS-6000 briefly. Spectral platform: teleph...

Read More
The Meaning and Analysis of Luminous Intensity Distribution
26 Sep, 2017 3853 Author: root

The Meaning and Analysis of Luminous Intensity Distribution

For lighting purpose, the luminaries playing a important role. A good lighting design is achieved by the choice of appropriate luminaires. The nature of the light emitted by the lamp and light control depend on the type of light source, the lamp reflection and the transmitting system and various dimming devices etc. It mainly reflects in the distribution curve of lamps. Light distribution curve is...

Read More
How to choose the right goniophotometer according to the standard LM-79 and EN13032-1?
18 Aug, 2017 7295 Author: root

How to choose the right goniophotometer according to the standard LM-79 and EN13032-1?

There is a wide range of goniophotometers on sale in the market, including central rotation type, rotation mirror type, double mirror type and so on. How to choose the corresponding goniophotometers for the tested lamps becomes the most important problem for the users. This article makes a brief introduction to this knowledge based on LM-79 and EN 13032-1. A-α B-β and C-γ Co-ordinate System A...

Read More
LISUN New Product! – LED Power Driver Aging Rack According to IEC62384
23 Jun, 2017 3276 Author: root

LISUN New Product! – LED Power Driver Aging Rack According to IEC62384

The quality of LED driver will influence the life of LED lamp directly. Therefore, we need to control the quality of LED driver strictly. According to IEC62384-2011 and GB/T 24825-2009 DC OR AC SUPPLIED ELECTRONIC CONTROL GEAR FOR LED MODULES – PERFORMANCE REQUIREMENTS. The control gear shall be subjected to a temperature cycling shock test and a supply voltage switching test as follows: a. Temp...

Read More
IEC 61000-4-2 ESD electrostatic discharge immunity test
23 Jun, 2017 4872 Author: root

IEC 61000-4-2 ESD electrostatic discharge immunity test

The International Electrotechnical Commission (IEC) has issued IEC 61000-4-2 Ed. 2.0 (2008-12) entitled “Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test.” This standard relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from opera...