Product No: SQ-010
The SQ-* Series Sulfur Dioxide Test Chamber is a testing device specially developed for simulating industrial corrosive environments. Its core function is to accurately control the concentration of sulfur dioxide (SO₂) gas and temperature to simulate sulfur dioxide corrosion environments in industrial atmospheres. This accelerates the evaluation of sulfidation corrosion resistance of metal materials, coatings, platings, and complete products, enabling rapid identification of material protection defects or product structural design vulnerabilities. It provides a scientific basis for verifying the corrosion resistance of industrial equipment, building materials, and hardware products.
The SQ-* Series Sulfur Dioxide Test Chamber features a studio made of imported corrosion-resistant PP sheets with integral molding (no welding seams, preventing gas leakage and cabinet corrosion). It utilizes U-shaped titanium alloy high-speed heating electric tubes, combined with a high-precision gas concentration control system and temperature coordinated control module. Additionally, it is equipped with intelligent functions such as automatic gas replenishment, real-time monitoring of gas concentration, and test time timing.
Standard:
Standard No. | Standard Name |
IEC 60068-2-42:2013 | Environmental testing – Part 2-42: Tests – Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-43:2013 | Environmental testing – Part 2-43: Tests – Test Kd: Hydrogen sulphide test for contacts and connections |
ISO 6988:1985 | Metallic and other inorganic coatings – Corrosion test in artificial atmospheres – Sulphur dioxide test |
DIN 50018:2017 | Corrosion tests in artificial atmospheres – Sulfur dioxide test |
ASTM G87-2015 | Standard Practice for Conducting Corrosion Tests in a Sulfur Dioxide Environment |
ASTM B845-2020 | Standard Practice for Sulfur Dioxide Corrosion Testing |
GB/T 2423.19-2013 | 环境试验 第 2 部分:试验方法 试验 Kc:接触点和连接件的二氧化硫试验 |
GB/T 2423.20-2014 | 环境试验 第 2 部分:试验方法 试验 Kd:交变盐雾(氯化钠溶液)与二氧化硫试验 |
GB/T 2423.33-2005 | 环境试验 第 2 部分:试验方法 试验 Kca:高浓度二氧化硫试验 |
GB/T 9789-2008 | 金属和其他无机覆盖层 通常凝露条件下的二氧化硫腐蚀试验 |
GB/T 5938-2017 | 轻工产品金属镀层和化学处理层的耐腐蚀性测试方法 |
GB 25972-2010 | 气体灭火系统及部件 |
Note:
There are slight differences in the testing requirements for sulfur dioxide test chambers across different standards. For specific details on which standards each model of LISUN’s sulfur dioxide test chambers complies with, it is recommended that you confirm with LISUN engineers to accurately match your testing needs.
Specifications:
LISUN Model | Chamber Dimensions (mm) | External Dimensions (mm) | Voltage | Power(KW) |
SQ-150 | 450*600*400 | 800*1070*1050 | AC220 | 2.5 |
SQ-250 | 600*900*500 | 870*1400*1150 | AC220 | 3 |
SQ-750 | 750*1100*500 | 1030*1680*1260 | AC220 | 4 |
SQ-010 | 850*1300*600 | 1160*2000*1390 | AC380 | 6 |
SQ-016 | 850*1600*600 | 1280*2320*1500 | AC380 | 7.5 |
SQ-020 | 900*2000*600 | 1220*2530*1410 | AC380 | 9 |
Specification:
• Temperature Range: RT + 5℃ ~ +50℃ (RT = Room Temperature, referring to the ambient temperature of the equipment’s installation environment)
• Temperature Uniformity: ≤ ±2℃ (Indicates the maximum temperature difference between different positions within the test chamber’s working space under stable operating conditions)
• Temperature Fluctuation: ≤ ±1℃ / ±0.5℃ (Refers to the maximum deviation of the actual temperature in the test chamber from the set temperature during the test, with two optional precision specifications)
• Test Duration: 0~999 H (Hours), M (Minutes), S (Seconds) adjustable; cyclic spraying available (Supports setting of continuous or intermittent cyclic spraying modes according to test requirements)
• Sulfur Dioxide (SO₂) Concentration: 25 pphm (parts per hundred million) or 0.1% ~ 1% (volume percentage), both adjustable (Two concentration ranges optional to meet different standard requirements for sulfur dioxide corrosion testing)