  • TThe Test Pin of UL 1310 Figure 16.1 is a precision safety tool tailored for Class 2 power units—such as phone chargers, LED driver supplies, and low-voltage 安防 (security) device power sources. It verifies if hazardous live parts are accessible, featuring a 25.4mm stainless steel test finger (101.6mm long) to navigate tight gaps and a rounded R12.7mm head to avoid damaging delicate components. An insulated nylon handle ensures operator safety, while the 31.75mm tail diameter prevents over-insertion. With a cable-free design (compatible with optional low-voltage test supplies), it applies gentle 10N thrust to mimic accidental contact, strictly complying with UL 1310 to keep Class 2 power equipment safe.

    NOTE: Please note SMT-S2962 is without cable. If you want to test with low-voltage supply with LISUN SMT-529CV, you may choose SMT-1213C with cables. 

    Standards:

    Standards No. Clause/Figure Standards Name
    UL 1310:2023 Clause 16.1, Figure 16.1 Standard for Safety for Class 2 Power Units
    CSA C22.2 No. 1310:2023 Clause 16.1, Figure 16.1 Safety Standard for Class 2 Power Units
    IEC 61032:2017 Clause 5.3, Figure 2 (Test Probe B) Test probes for protection against access to hazardous parts
    UL 60335-1:2023 Clause 22.5, Figure 22.5 Standard for Safety for Household and Similar Electrical Appliances – Part 1: General Requirements
    UL 1082:2023 Clause 8.3, Reference Figure for Probe Standard for Safety for Household Electric Coffee Makers and Brewing-Type Appliances
    UL 1082:2023 Clause 8.3, Reference Figure for Probe Standard for Safety for Household Electric Coffee Makers and Brewing-Type Appliances

    Specifications:
    Tool Type: Test Pin (UL 1310 Figure 16.1; for hazardous live part accessibility testing in Class 2 power units)
    Test Finger Material: Stainless steel (resistance ≤ 0.1Ω; corrosion-resistant; smooth finish to protect power unit components)
    Handle Material: Insulated nylon (resistance ≥ 100MΩ; heat-resistant up to 110°C; ergonomic non-slip grip for precision)
    Key Dimensions:
    – Test Finger Diameter: 25.4mm (1 inch) ± 0.1mm
    – Test Finger Length: 101.6mm (4 inches) ± 0.2mm
    – Head Radius: R12.7mm (0.5 inch) ± 0.05mm
    – Tail Diameter: 31.75mm (1.25 inches) ± 0.2mm
    – Total Length (Probe + Handle): 320mm ± 0.5mm
    Applied Thrust: 10N ± 0.5N (simulates gentle accidental contact; aligns with Class 2 power unit safety test requirements)
    Cable Configuration: Cable-free design (compatible with optional low-voltage test supplies for extended live-part detection)
    Core Function: Detects accessible hazardous live parts in Class 2 power units; prevents over-insertion via tail; ensures UL/CSA/IEC compliance

    Test Procedures:
    1. Inspect the test pin for bent fingers, cracked insulation, or surface damage; confirm conductivity with a test tool.
    2. Power on the Class 2 power unit under test (EUT, e.g., a phone charger) and set it to normal operating mode.
    3. Hold the nylon handle, align the 25.4mm test finger with EUT gaps (e.g., charger port seams, case slots).
    4. Apply steady 10N thrust—stop if resistance blocks insertion or the tail touches the EUT.
    5. Check the connected live-part detector for signals (indicating contact with hazardous parts).
    Record results: Pass if no contact; Fail if the probe reaches dangerous components.

    Applications:
    1. Testing access to live terminals in phone charger casings (per UL 1310:2023 Figure 16.1) to prevent electric shock.
    2. Verifying LED driver power supply gaps (compliant with CSA C22.2 No. 1310:2023) to block contact with internal circuits.
    3. Safety checks for low-voltage 安防 device power units (per IEC 61032:2017 Figure 2) to avoid live-part exposure.
    4. Quality control for portable speaker chargers during manufacturing, ensuring UL 1310 compliance.
    5. Post-production testing of smart home device power adapters to meet global Class 2 power unit safety standards.