+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
What’s the difference of Needle flame and horizontal & vertical flame test?
17 Jul, 2020 2815 Author: Cherry Shen

What’s the difference of Needle flame and horizontal & vertical flame test?

ZY-3 Needle flame tester is mainly used for testing lighting equipment, low-voltage electrical appliances, household appliances, power tools, electronic instruments, electronic instruments, etc. At the same time, this instrument is also suitable for testing insulating materials, engineering plastics and solid flammable materials. Comply with IEC60695-2-2 (2004), GB5169.5-2008, GB4706.1 and other t...

Read More
Relevant standards for EMC testing of automotive electronics
15 Jul, 2020 2965 Author: Cherry Shen

Relevant standards for EMC testing of automotive electronics

Electrical and radio-frequency disturbances occur during normal operation of many items of motor vehicle equipment. They are generated over a wide frequency range and can be distributed to on-board electronic devices and systems by conduction, coupling or radiation. In recent years, an increasing number of electronic devices for controlling, monitoring and displaying a variety of functions have be...

Read More
How to choose magnetic shielding room for EMI test
03 Jul, 2020 2878 Author: Cherry Shen

How to choose magnetic shielding room for EMI test

Working principle of shielding room: Computers, communicators, and electronic equipment will generate electromagnetic waves of certain strength during normal operation. The electromagnetic waves may interfere with other equipment or be received by special equipment to steal their work. At the same time, these electronic devices also need to ensure their normal operation in an electromagnetic envir...

Read More
Glow-wire test work principle introduction and application
15 Jun, 2020 3351 Author: Cherry Shen

Glow-wire test work principle introduction and application

The glow wire test is to test the stability of electronic and electrical products at work. The glow wire itself is actually a fixed-size resistance wire ring. During the test, it is heated to the specified temperature with electricity, so that the tip of the glow wire contacts the sample to reach the standard required time, and then observe and measure its state. The test range depends on the spec...

Read More
How to choose a suitable electrostatic electret generator according to international standards?
11 Jun, 2020 2999 Author: Cherry Shen

How to choose a suitable electrostatic electret generator according to international standards?

Melt-blown non-woven fabrics are widely used in the field of filter materials, and can be described as the “heart” of the mask structure. The average fiber diameter of polypropylene melt-blown fabrics is 2 to 5 μm, and the droplets with a particle size of more than 5 μm in the air can be blocked.  But can only block less than 70% of the particles. Even if the barrier rate is increas...

Read More
How to choose the right electrostatic electret generator for meltblown cloth? Do you really need 120KV?
11 Jun, 2020 2598 Author: Cherry Shen

How to choose the right electrostatic electret generator for meltblown cloth? Do you really need 120KV?

Mr. Wang was the earliest batch of melt-blown fabric bosses in Yangzhong. Due to the strict management of the government and the strict requirements on the quality of melt-blown fabrics by mask manufacturers, Mr. Wang is talking to  engineer Liu, an expert on melt-blown fabrics  who Secretary Zhang has invited today, to talk about how to transform his several production lines. Secretary Zhang: B...

Read More
Can PFE filterability reach 95% after 3-5 days of your meltblown cloth?
11 Jun, 2020 3384 Author: Cherry Shen

Can PFE filterability reach 95% after 3-5 days of your meltblown cloth?

Recently, a news broke the circle of friends: the United States released a test report on Chinese masks, and over 80% of Chinese companies were suddenly “deprived” of export authorization! Late at night on May 7th, Beijing time, the US Centers for Disease Control and Prevention (CDC) suddenly issued a test report for Chinese masks through its official website, and 105 Chinese masks wer...

Read More
How to choose the right electrostatic electret generator
11 Jun, 2020 2842 Author: Cherry Shen

How to choose the right electrostatic electret generator

As the US FDA/CDC canceled nearly 80% of the mask whitelist companies in China, it encountered the Canadian government requiring dozens of Chinese mask factories to recall unqualified products on their own. Since May, many people in the mask chain industry have discussed that this industry has entered the bottom. We believe that as long as the new crown special drugs or vaccines do not appear, glo...

Read More
The meaning of ultraviolet rays, wavelength band (UVA, UVB, UVC) and hazards
11 Jun, 2020 6467 Author: Cherry Shen

The meaning of ultraviolet rays, wavelength band (UVA, UVB, UVC) and hazards

Ultraviolet rays are rays of sunlight with a wavelength of 100 to 400 nanometers (nm). English is ultraviolet, ultra- means above, beyond. The frequency of ultraviolet rays in the solar spectrum is higher than that of visible rays. Can be divided into UVA (ultraviolet A, wavelength 320-400 nm, long wave), UVB (wavelength 280-320 nm, medium wave), UVC (wavelength 100-280 nm, short wave). Among them...

Read More