+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
Standard for testing ultraviolet intensity of UV (ultraviolet) lamps used for disinfection
02 Apr, 2020 3052 Author: Cherry Shen

Standard for testing ultraviolet intensity of UV (ultraviolet) lamps used for disinfection

The principle of ultraviolet disinfection is to use ultraviolet radiation to cause photolysis and denaturation of bacteria proteins, and the amino acids, nucleic acids and enzymes of bacteria are destroyed and died. At the same time, when the ultraviolet rays pass through the air, the oxygen in the air is ionized to generate ozone, which strengthens the bactericidal effect. Ultraviolet is mostly u...

Read More
Uses of UV lamps and test methods for UV lamps
25 Mar, 2020 2829 Author: Cherry Shen

Uses of UV lamps and test methods for UV lamps

Ultraviolet lamps can be used for ultraviolet sterilization, excitation fluorescence (fluorescence microscope, banknote detection), trapping and killing insects, and printing. Curing three-dimensional parts of different shapes and sizes, angles and bends, edges and bumps requires light to be projected onto all surfaces and should have sufficient energy. Generally, the lamp is composed of a lamp tu...

Read More
IK01-10 IK Level Tester is Designed According to IEC 60068-2-75: Tests- Test Eh: Hammer tests.
20 Mar, 2020 3975 Author: Cherry Shen

IK01-10 IK Level Tester is Designed According to IEC 60068-2-75: Tests- Test Eh: Hammer tests.

The full name of IEC 60068-2-75 is Environmental testing-Part 2-75: Tests- Test Eh: Hammer tests. It has been prepared by IEC technical committee 104:Environmental conditions, classification and methods of test. We will introduce the IEC 60068-2-75-1 Scope The following is the original content of IEC 60068-2-75-1. IEC 60068-2-75-1 Scope This part of IEC 60068 provides three standardized and coordi...

Read More
How to test LED fixture for startup, rise time and flicker
18 Mar, 2020 2825 Author: Cherry Shen

How to test LED fixture for startup, rise time and flicker

In recent years, the LED market has been expanding, which is attributed to the unique characteristics of LED solid-state lighting products, such as good luminous efficiency, long service life and high reliability .Therefore, LED solid-state lighting products are increasingly favored by the market and consumers. But at the same time, because of the fast response speed of LED and the lack of thermal...

Read More
GDJS/GDJW High and Low Temperature Humidity Chamber is Designed According to IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold
12 Mar, 2020 2958 Author: Cherry Shen

GDJS/GDJW High and Low Temperature Humidity Chamber is Designed According to IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold

The full name of IEC 60068-2-1 is Environmental Testing Part 2-1: Tests-Test A: Cold. It is edited by the IEC technical committee in 2008.We will introduce the IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold The following is the original content of IEC 60068-2-1 IEC 60068-2-1 Environmental Testing Part 2-1: Tests-Test A: Cold This part of IEC 60068 deal with cold tests applicalbe ...

Read More
LSG-6000 Goniophotometer is Designed According to EN 13032-16.1.1.3 Goniophotometer type 3
05 Mar, 2020 3380 Author: Cherry Shen

LSG-6000 Goniophotometer is Designed According to EN 13032-16.1.1.3 Goniophotometer type 3

The full name of EN13032-1 is Light and lighting Measurement and Presentation of photometric data of lamps and luminaires. It is edited by CEN in 2004. This standard is a guide to procedures referring where necessary to the relevant CIE, ISO and CEN publications . We will introduce the clause 6.1.1.3 Goniophotometer type 3 in this article. The following is the original content of EN 13032-1 6.1.1....

Read More
LPCE-3 CCD Spectroradiometer Integrating Sphere Compact System is Designed According to IES LM-79-08 9.1 Integrating Sphere with a Spctroradiometer(Sphere-spectroradiometer System)
02 Mar, 2020 2880 Author: Cherry Shen

LPCE-3 CCD Spectroradiometer Integrating Sphere Compact System is Designed According to IES LM-79-08 9.1 Integrating Sphere with a Spctroradiometer(Sphere-spectroradiometer System)

The full name of IES LM-79-08 is Electrical and Photometric Measurements of Solid-State Lighting Products. It is edited by the Illuminating Engineering Society in 2008. This approved method is a guide developed for the measurement of solid state lighting products. We will introduce the clause 9.1 Integrating Sphere with a Spectroradiometer(Sphere-spectroradiometer System) in this article. The foll...

Read More
Interpretation of the latest American Energy Star IES LM-79-19 standard
07 Jan, 2020 5061 Author: root

Interpretation of the latest American Energy Star IES LM-79-19 standard

LM-79-19 English Version Free Download: Click Here LM-79-19 Spanish Version Free Download: Click Here LM-79-19 Chinese Version Free Download: Click Here ANSI (American National Standards Institute) and IES(Illuminating Engineering Society of North America) officially released the latest version of the IES LM-79-19 standard in May 2019, it will replace the LM-79-08 version. LISUN interpreted the ne...

Read More
Comparative Evaluation between ANSI / IES Standards LM-79-19 and LM-79-08
08 Dec, 2019 8089 Author: root

Comparative Evaluation between ANSI / IES Standards LM-79-19 and LM-79-08

LM-79-19 English Version Free Download: Click Here LM-79-19 Spanish Version Free Download: Click Here LM-79-19 Chinese Version Free Download: Click Here This article tries to make a comparative evaluation between ANSI/IES LM-79-19 Standard that has replaced ANSI/IES LM-79-08 that deals with the methods approved by ANSI/IES regarding performance, requirements technicians of photometric and electri...

Read More