Product No: LS-B48
IEC 60811-1-2 Clause 8.2 and 8.3 | IEC 60335-1 Clause 22.32 Oxygen Bomb Air Aging Test Chamber combines simulated media environment with precise temperature and pressure control, specifically designed for testing the aging performance of various polymer materials. The equipment can simulate the aging environment that materials may face in actual use under specific gas media, temperature, and pressure conditions, evaluating the durability and stability of materials through accelerated aging tests. It features automatic temperature control, pressure control, and pressure relief functions, ensuring the standardization and safety of the testing process. It is also adaptable to the testing needs of different types of materials, providing reliable test data support for material research and development, quality inspection, and compliance verification.
Standards:
| Standard No. | Standard Name |
| IEC 60811-1-2:2014 | Electric and optical fibre cables – Test methods for non-metallic materials – Part 1-2: General test methods – Aging |
| IEC 60335-1:2023 | Household and similar electrical appliances – Safety – Part 1: General requirements |
| IEC 60245-1:2003+AMD1:2011+AMD2:2017 | Rubber insulated cables – Rated voltages up to and including 450/750 V – Part 1: General requirements |
| GB/T 2951.12-2021 | 电缆和光缆绝缘和护套材料通用试验方法 第 12 部分:通用试验方法 老化试验 |
| GB/T 4706.1-2023 | 家用和类似用途电器的安全 第 1 部分:通用要求 |
| GB/T 5013.1-2018 | 额定电压 450/750V 及以下橡皮绝缘电缆 第 1 部分:一般要求 |
Specification:
| Air Bomb Test | The medium is air, the temperature is 127℃, and the working pressure is 0.55±0.02 MPa (in accordance with standards such as IEC 60811-1-2 Clause 8.2). |
| Oxygen Bomb Test | The medium is oxygen with a purity of not less than 97%, the temperature is 70℃, and the working pressure is 2.1±0.07 MPa (in accordance with standards such as IEC 60811-1-2 Clause 8.3). |
| Working Pressure | ≤2.5MPa |
| Pressure Display Accuracy | 0.02MPa |
| Temperature Automatic Control Range | Room temperature~150℃ |
| Temperature Deviation | ±0.5℃ |
| Cabinet Size | 840*420*880mm |
| Tank Volume | ≥4000cm³ |
| Pressure Reduction Program | After the test, the test chamber automatically relieves pressure gradually, with the pressure relief time not less than 5 minutes until the pressure drops to atmospheric pressure. |
| Built-in Timer | 0.01s~999.9s/m/h Arbitrary Setting |
| Power Supply Voltage | AC220~240V 50/60Hz |
| Air/Oxygen Source | Customer Prepared: Compressed air and oxygen with a purity of not less than 97% |

IEC 60811-1-2 Clause 8.2 and 8.3