Product No: RFCI61000-6
RFCI61000-6 RF Conducted Immunity Test System is specially developed for civilian RF field induced conducted immunity testing. It fully complies with domestic and foreign civil electromagnetic compatibility standards such as IEC61000-4-6, GB/T 17626.6, etc. It is mainly used for power lines and signal lines of lighting, medical, electric power, industrial control, new energy, communications and other types of civilian electronic equipment at 150kHz~230MHz. The RF conducted interference immunity test evaluates the working stability and reliability of the equipment in a continuous RF conducted interference environment. It is widely adapted to enterprise research and development, product finalization and third-party laboratory compliance testing.
RFCI61000-6 RF Conducted Immunity Test System has a built-in signal synthesizer, a three-channel high-precision power meter, an RF power amplifier and a dual directional coupler. It is compatible with CW, AM, PM modulation and unmodulated signal modes. It supports average mode or pulse mode to detect amplitude modulated or pulse modulated signals. It can be equipped with CDN coupling decoupling network, electromagnetic injection clamp, and current injection clamp for multiple injection methods. One-click fully automatic full-band calibration takes less than 1 minute.
Standards:
| Standards No. | Standards Name |
| IEC 61000-4-6:2023 | Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields |
| EN 61000-4-6:2023 | Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields |
| GB/T 17626.6-2017 | 电磁兼容 试验和测量技术 射频场感应的传导骚扰抗扰度 |
Specifications:
| Signal Generator | |
| Frequency Range | 100kHz~300MHz |
| Frequency Resolution | 1Hz |
| Frequency-temperature Stability | ±0.5ppm |
| Harmonics | ≤-30dBc |
| Anharmonic | ≤-50dBc |
| Output Power Range | -100dBm~3dBm |
| Amplitude Modulation | Modulation frequency: 1 Hz–10 kHz; modulation depth: 1%–99%; internal/external modulation |
| Pulse Modulation | Modulation frequency: 1 Hz–10 kHz; Duty cycle: 1%–99% |
| Power Meter*3 | |
| Frequency Range | 100kHz-300MHz |
| Input Tange | -85dBm-+10dBm |
| Accuracy | ±0.5 dB |
| Sampling Mode | Average, Integration, Pulse |
| Input Interface | Front-panel SMA, rear-panel N-type connector |
| Power Amplifier | |
| Standards | IEC61000-4-6 |
| Frequency Range | 100kHz~300MHz |
| Output Power | 80W |
| Output Interface | Rear panel N-type connector |
| Dual Directional Coupler | |
| Frequency Range | 100kHz~300MHz |
| Attenuation Ratio | 50dB |
| Maximum Input Power | 100W |
| General Parameters | |
| Output Frequency Range | 150kHz~230MHz |
| Output Voltage (CDN method) | 1~30Vrms |
| Output Voltage (EM clamp method) | 1~18Vrms |
| Output Voltage (current clamp method) | 1~10Vrms |
| Included Accessories | Attenuator: Frequency range DC–3 GHz, N-type connector |
| Communication Interface | LAN、USB、RS485 |
| Control System | 10.1-inch Android capacitive touchscreen display (Chinese/English) + supports remote control via PC software |
| Operating Environment | Temperature: 10°C–40°C, Humidity: 30%–70% |
| Power Supply | AC:100~250V@50Hz/60Hz |
| Dimension | 4U/19″ Standard Chamber |

IEC 61000-4-6 Measured Waveform
Instructions:
Please refer to Figure 20 of Section 7.4.2 of IEC 61000-4-6:2023 or GB/T 17626.6-2017 to select the following injection method: CDN method, electromagnetic clamp method, or current clamp method.

Figure 20 – Rules for selecting the injection method
Recommendation 1:
The RFCI61000-6 series can be used with the following LISUN CDN coupling and decoupling networks to perform CDN injection testing on the EUT (Please refer to IEC 61000-4-6:2023 Clause 6.2.2 and Table 4 to select the right CDN to test):

CDN for RF Conducted Immunity Test
| CDN Types | LISUN Model | Test Ports | Power |
| Power Supply Cables | CDN-M1-16 | Single -phase single-wire power cable (L) | 220V/16A |
| CDN-M1-32 | Single -phase single-wire power cable (L) | 220V/32A | |
| CDN-M2-16 | Single -phase two-wire power cable (L/N) | 220V/16A | |
| CDN-M2-32 | Single -phase two-wire power cable (L/N) | 220V/32A | |
| CDN-M2-100 | Single -phase two-wire power cable (L/N) | 220V/100A | |
| CDN-M3-16 | Single -phase three-wire power cable (L/N/PE) | 220V/16A | |
| CDN-M3-32 | Single -phase three-wire power cable (L/N/PE) | 220V/32A | |
| CDN-M3-100 | Single -phase three-wire power cable (L/N/PE) | 220V/100A | |
| CDN-M3-32-3 | Three -phase and three-wire power cable (3L) | 380V/32A | |
| CDN-M4-32 | Three -phase and four-wire power cable (3L/1N) | 380V/32A | |
| CDN-M4-100 | Three -phase and four-wire power cable (3L/1N) | 380V/100A | |
| CDN-M4-32-PE | Three -phase and four-wire power cable (3L/1PE) | 380V/32A | |
| CDN-M5-32 | Three -phase and five-wire power cable (3L/1N/1PE) | 380V/32A | |
| CDN-M5-100 | Three -phase and five-wire power cable (3L/1N/1PE) | 380V/100A | |
| Unscreened Balanced Lines | CDN-T2 | 2 line | 100V/5A |
| CDN-T4 | 4 line | 100V/5A | |
| CDN-T8 | 8 line with RJ45 port | 100V/5A | |
| Unscreened Unbalanced Lines | CDN-AF2 | 2 line | 100V/5A |
| CDN-AF4 | 4 line | 100V/5A | |
| CDN-AF8 | 8 line | 100V/5A | |
| Screened Cables | CDN-S1 | single line with BNC port | 100V/5A |
| CDN-S4 | 4 line with USB ports | 100V/5A | |
| CDN-S8 | 8 line with RJ45 port | 100V/5A | |
| CDN calibrating jigs | CDN-CS100 | Including 150Ω-50Ω adapter resistors. Note: If one or more CDNs are purchased, one set of CDN-CS100 must be selected. | |
Recommendation 2:
The RFCI61000-6 series can be used with the LISUN AB-EM electromagnetic injection clamp to perform electromagnetic injection testing on the EUT, which is fully according to IEC 61000-4-6:2023 Clause 6.2.3.3.

AB-EM Electromagnetic Clamp for RF Conducted Immunity Test
• Injection power: Maximum 100W (5 minutes)
• Injection frequency: 150kHz~400MHz
• Coupling/decoupling directivity: Greater than 10dB (>10MHz)
Recommendation 3:
The RFCI61000-6 series can be used with the LISUN AB-100W current injection clamp to test signal lines of any specifications, which is fully according to IEC 61000-4-6:2023 Clause 6.2.3.2.

AB-100W Current Injection Clamp for RF Conducted Immunity Test
• Supports testing of any signal cable specification: unshielded balanced cables (T2, T4, T8), unshielded unbalanced cables (AF2, AF4, AF8), communication cables (RJ11, RJ11S, RJ45, RJ45S, USB-C, USB-P), and any other cable specification
• Maximum supported cable diameter: 40mm
• Maximum output power: 100W
• Frequency range: 100kHz to 300MHz
• Insertion loss: <7dB
• Includes standard current clamp calibration kits
LISUN's Motor-Operated Tool | Power Tool Testing solutions strictly comply with a range of core...
LISUN's electric toys test solutions are engineered to meet the stringent requirements of key...
LISUN's transformer test solutions are designed to meet the comprehensive requirements of...
LISUN's energy meter test solutions are designed to ensure the accuracy and reliability of...
This Indonesia-based product certification body and testing laboratory is one of the leading quality testing and...
In the field of testing, certification, and inspection, this testing laboratory has consistently proven to be a...
The customer in this case is a leading high-quality sensor manufacturer in South Korea, specializing in the field of...
As a leading benchmark in Russia’s lighting industry, this enterprise is positioned around providing...
I. Company Overview: A Benchmark in Full-Scene Lighting Solutions As a leading lighting enterprise and prominent LED...
One of the electromagnetic compatibility tests is a continuously performed radiofrequency (RF)...
Abstract As the complexity of electronic devices continues to increase, ensuring electromagnetic...
What is RF Immunity Test: RF Conducted Immunity Testing is a common electromagnetic compatibility...
Abstract The RF conducted immunity test system is a crucial tool for assessing the immunity to...
Introduction The RF Conducted Immunity Test System is an essential component in the field of...