Product No: DSCD-910
Benchtop Spectrophotometer (Transmittance) DSCD-910 is good performance and specially designed for testing the transparent material’s transmittance, absorbance, chromaticity value and other parameters.
The instrument adopts the geometry of D/0, integration of the full band LED composite light source, double beam optical system, ETC every-test calibration technology, which makes the instrument reaches a resolution of 0.0001, deviation of the transmittance within 0.08% and chromatic value △E*ab 0.015.
Brief Introduction
• D\0 Structure
• It is suitable for testing the glass and liquid color
• Adopt UV enhanced silicon photodiode
Expend the transmittance from 0~100% to 0~200%.
• It can also be used for measure APHA/Pt-Co, Gardner,ASTM color, Yellowness Index for liquid and transparent materials.
• Color QC software
Our spectrophotometer comes with free color QC software, which is applicable in various industries for management of color data. It is used for store test result,generate test report and print test report after connect with printer.
Specifications:
LISUN Model | DSCD-910 |
Illumination | d/0 (Diffused illumination, 0°viewing) SCS optical engine (light splitting and integration system), (conform to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition standards) |
Size of integrating sphere | Φ40mm, Alvan diffused reflection surface coating |
Illumination Light source | CLEDs (entire wavelength balanced LED light source) |
Sensor | dual light path sensor array |
Wavelength range | 400-700nm |
Wavelength interval | 10nm |
Half spectral width | 5nm |
Reflectivity range | 0-200% |
Reflectivity resolution | 0.01% |
Observation angle | 2°/10° |
Measurement light source | A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, DLF, NBF, TL83, TL84 |
Data being displayed | Transmittance graph/value, chromatic value, color difference values, color assessment results, color tendency, history color value simulation, manual input standard sample, generate measurement reports |
Measurement time interval | 2 seconds |
Measurement time | 0.5 seconds |
Color space | CIE-L*a*b, L*C*h, CIE-L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell MI, CMYK |
Color difference formulas | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*94, ΔE*00, ΔEab (Hunter), color classification |
Other colorimetric indices | WI (ASTM E313-10, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Tint (ASTM E313-00, CIE, Ganz), Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner |
Repeatability | light splitting reflectivity: standard deviation within 0.08% |
color values: ΔE*ab <=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals, Maximum: 0.03) | |
Interface | USB |
Data storage | mass storage |
Light source longevity | 5 years, 1.5 million tests |
Size | 475*340*150mm (L*W*H) |
Weight | about 7kg |
Work temperature range | 0~45℃, relative humidity 80% or below (at 35°C), no condensation |
Storage temperature range | 25℃ to 55℃, relative humidity 80% or below (at 35°C), no condensation |
Standard accessories | AC power line, color management software, drive software, USB cable, black calibration tube, 40*10mm cuvette |
Applications: