IEC 60099-4:2014 is an international standard specifying technical requirements, test methods, and performance criteria for gapless metal-oxide surge arresters (MOSAs) used in alternating current (a.c.) power systems. It focuses on arresters designed to protect electrical equipment from transient overvoltages, such as those caused by lightning or switching operations, by leveraging the nonlinear voltage-current characteristics of metal-oxide materials. The standard defines key parameters including rated voltage, residual voltage, discharge capacity, and thermal stability, while outlining uniform testing procedures to verify arrester reliability under normal and fault conditions—ensuring consistency in product performance across global markets.
This standard applies to gapless MOSAs for a.c. systems with nominal voltages ≥1 kV, covering design, manufacturing, and conformity assessment aspects. It addresses critical requirements such as mechanical strength, environmental resistance (e.g., temperature, humidity), and aging characteristics to guarantee long-term operational safety. Additionally, IEC 60099-4:2014 aligns with other IEC standards (e.g., IEC 60099-1) to establish a comprehensive framework for surge arrester qualification, facilitating interoperability between arresters and power system components. It serves as a foundational reference for manufacturers, utilities, and certification bodies to ensure products meet global safety and performance benchmarks, supporting the reliable operation of electrical grids worldwide.
LISUN supplies the fully test solutions for the following IEC 60099-4:2014, please see the below excel table:
| IEC 60099-4:2014 Clause and Subject | LISUN MODEL |
| 6.1 Insulation withstand | LS9923 |
| 8.2 Insulation withstand tests | |
| 8.2.6 Lightning impulse voltage test | SUG255 |
| 8.2.7 Switching impulse voltage test | |
| 8.3 Residual voltage tests | LS-RVT-2000W |
| 8.9.4.2 Bending moment test | JCY-2 |
| 8.9.5 Temperature cycling and seal pumping test | GDJS-015B |
| 8.12.3.1 Temperature cycling test | |
| 8.16.2 Thermal cyclic test | |
| 8.12.3.2 Salt mist test | YWX/Q-010 |
| 10.8.17.2 Salt fog test | |
| 10.8.17.3 UV light test | UV-263LS |