  • The LS-RVT-2000W Residual Voltage Tester (Residual Voltage Tester / Peak Power-Off Device) is a specialized instrument focused on detecting residual voltage in electrical equipment. It can disconnect the tested equipment from the mains voltage at voltage peaks, and maintains sufficiently high insulation resistance after circuit disconnection to simulate a plug-and-unplugged scenario. The instrument accurately measures the residual voltage after power failure, supports multiple cyclic tests, automatically records test data and calculates relevant statistical values, and features audible and visual alarms. It can promptly cut off the voltage when the detected value exceeds the set range, providing accurate and reliable testing support for verifying the safety performance of electrical equipment.

    Standards:

    Standards No. Standards Name
    IEC 60335-1:2023 Household and similar electrical appliances – Safety – Part 1: General requirements
    IEC 60065:2014 Audio, video and similar electronic apparatus – Safety requirements
    IEC 60601-1:2020 Medical electrical equipment – Part 1: General requirements for basic safety and essential performance
    IEC 60598-1:2021 Luminaires – Part 1: General requirements and tests
    IEC 60950-1:2005 Information technology equipment – Safety – Part 1: General requirements
    GB/T 4706.1-2024 家用和类似用途电器的安全 第 1 部分:通用要求
    GB 8898-2011 音频、视频及类似电子设备 第 1 部分:通用要求
    GB 9706.1-2020 医用电气设备 第 1 部分:基本安全和基本性能的通用要求
    GB 7000.1-2015 灯具 第 1 部分:一般要求和试验
    GB 4943.1-2022 信息技术设备 安全 第 1 部分:通用要求

    Specification:

    LISUN Model LS-RVT-2000W LS-RVT-4000W
    Output Max Power/Current 2000W/10A Single Phase 4000W/16A Single Phase
    Output Voltage Range AC 0~250V (Adjustable)
    Residual Voltage Testing Range 5~199.9V; Resolution: 0.1V, Accuracy: ±(reading*1%+1V)
    Testing Time 1~99 seconds
    Testing Impedance 1000 MΩ
    Testing Alarm Range 5~100V
    Test Judgment Sound and light alarm, and voltage cut off at the same time
    Communication Port RS-485
    Figure 1 Monitoring interface of LS-RVT

    Figure 1 Monitoring interface of LS-RVT

    1) Voltage display: Display the output voltage of the regulator, output this voltage when starting the test; (unit: V)
    2) The current display: Display the current of the samples during the test; (unit: A)
    3) Power display: Show the sample consumption power during testing; (unit: W)
    4) Residual voltage: Display the remaining voltage of the sample plug in the sample plug during testing; (unit: V)
    5) Time display: Display the countdown of power -powered time and power -off time; (unit: S)
    6) The Residual Voltage test value list: Display the Residual Voltage test value of the cycle test at the first to 10 times during testing; (unit: V)
    7) Residual Voltage calculation value: Display the maximum, minimum value, and arithmetic average of the Residual Voltage test value list; (unit: V)
    8) Set button: Click to enter the parameter setting interface;

    Figure 2 Set Interface of LS-RVT

    Figure 2 Set Interface of LS-RVT

    9) Electrical power: Set the power supply time to the sample; 3 seconds by default;
    10) Cyclic measurement: Set the number of continuous tests; 10 times by default;
    11) Delay measurement: Set the Residual Voltage corresponding to the delay time after the measurement of the sample; 1 second by default;
    12) Power off angle: Set the control phase angle of the voltage;  90/270 degrees at the peak by default;
    13) Alarm voltage: Set the upper limit of the Residual voltage;
    14) Measurement items selection: The measurement items are L/N, L/E, N/E. Select the residual voltage test between which two pins.
    15) Calibration button: click to enter the parameter calibration interface;
    16) Return button: Click to return to the monitoring interface;

    Standard:
    IEC60335-1 Clause 22.5 “Household and similar electrical appliances – Safety – Part 1: General requirements”

    IEC60335-1 Clause 22.5 Household and similar electrical appliances – Safety – Part 1: General requirements

    IEC 60065 Edition 7.1-2005 Clause 9.1.6″Audio, video and similar electronic apparatus – Safety requirements”

    IEC 60065 Edition 7.1-2005 Clause 9.1.6″Audio, video and similar electronic apparatus – Safety requirements”

    IEC 60601-1:2005 “Medical electrical equipment – Part 1: General requirements for basic safety and essential performance”

    IEC/EN 60598-1 -2008 Clause 8.2.7:” LUMINAIRES – Part 1: General requirements and tests”

    IEC/EN 60598-1 -2008 Clause 8.2.7:” LUMINAIRES – Part 1: General requirements and tests”