+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
27 Mar, 2023 653 Views Author: Cherry Shen

What causes the high and low temperature chamber compressor to restart continuously

The core component of the compressor in the refrigeration system is the core component of the high and low temperature chamber, which plays a decisive role in the whole refrigeration system. However, in general, the compressor should not be started more than 6 times per hour, otherwise it will be deemed as a failure.

What is the reason for the uninterrupted operation of the compressor?
1. The power supply voltage is too high or too low and unstable → After the power supply voltage returns to normal, it is necessary to connect the power supply or install an AC voltage stabilizer to provide a stable 380 for the test chamber. V power supply;
2. The door seal of the high and low temperature chamber is not tight, and the air leakage is serious. The door seal should be repaired, adjusted or replaced;

video

3. Overcurrent and over-temperature protection relay disc bimetallic sheet failure problem: replace with a new over-current and over-temperature protection relay;
4. The main reason for the poor heat dissipation of the condenser and the low heat dissipation rate of the condenser is that there is dirt on the surface of the condenser, and the ambient temperature in the high and low temperature test chamber is too high. Clean the condenser dirt regularly to improve the heat dissipation state of the high and low temperature chamber.

Common errors in high and low temperature chamber:
From the perspective of reliability of high and low temperature chamber, human error in high and low temperature chamber test can be divided into the following five types:
①. The design error violates the humanized design principle. Once the operation error occurs, it will cause equipment failure;
②. Process error, process does not meet the drawing and process requirements;
③. For inspection errors, products that do not exceed the allowable error are considered as unqualified products, or products that exceed the allowable error are considered as qualified products;
④. Errors in assembly and maintenance. Assembly and maintenance do not meet the drawing and technical requirements:
⑤. Errors in operation, non-standard operation, lack of necessary steps or addition of additional steps and operation sequence, etc., reversing the operation sequence, etc; Handle the above errors, which are generated during the transportation and storage of high and low temperature chamber. Even if the above errors occur, the system may not fail immediately. However, these factors are indeed the cause of system failure. In particular, the main reasons for equipment failure are that the necessary personnel and equipment, procedure tables, technical data, logistics and other elements are not complete, and the relevant regulations and procedures for use are incomplete.

How to solve the problem of no reaction in high and low temperature chamber?
1. Check whether the high and low temperature test box contacts well and whether the master switch contacts well/whether it is burnt, damaged, repaired or replaced;
2. Check whether the contactor or relay is in good contact or burnt or damaged;
3. Whether the overtemperature setting of the high and low temperature chamber meter is correct/whether it is burnt out, damaged, reset or replaced;
4. Check whether the phase sequence connection of the power incoming line (phase sequence relay) is correct or damaged, and reconnect/replace it;
5. Whether the pressure adjustment of the pressure controller is correct or damaged, readjust or replace it;
We can investigate the cause of the failure through the above points. According to the above analysis, only by deeply understanding the working principle and process of the high and low temperature chamber can we quickly solve the problems in the operation of the test chamber.

Temperature Humidity Chamber | Thermal Chamber | Climate Chamber is according to IEC60068-2-1 (GB/T2423.1) and IEC60068-2-2 (GB/T2423.2), IEC60068-2-78, IEC60598-1, GB/T2423.17, GB/T5170.2, GB/T5170.5. The climate chamber is used to test the CFL/LED which meets IES LM-80-08, electricity products, automative cars, home appications and mobiles.

What causes the high and low temperature chamber compressor to restart continuously

High and low Temperature & humidity chamber

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are GoniophotometerIntegrating SphereSpectroradiometerSurge GeneratorESD Simulator GunsEMI ReceiverEMC Test EquipmentElectrical Safety TesterEnvironmental ChamberTemperature ChamberClimate ChamberThermal ChamberSalt Spray TestDust Test ChamberWaterproof TestRoHS Test (EDXRF)Glow Wire Test and Needle Flame Test.

Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp:+8615317907381