How much impact does high and low temperature chamber on LED Lamps?

The high and low temperature environmental test chamber is also called the high and low temperature cycle test, which is one of the product environmental reliability tests. Basically all products are stored or operated under a certain temperature environment. In some environments, the temperature will constantly change, sometimes high and sometimes low. For example, the temperature in day and night in some areas are differences. Or the product repeatedly enters and exits the high temperature area and low temperature area during transportation, storage, and operation. This kind of high and low temperature environment may reach 70°C or even higher at high temperature, and the temperature may reach -20°C or lower at low temperature. This constantly changing temperature environment will affect the function, performance, quality and life of the product, accelerate the aging of the product, and shorten the service life of the product.

If the product is exposed to such a large alternating high temperature and low temperature environment for a long time, it needs to have sufficient resistance to high and low temperature cycles. In this way, we need to simulate certain environmental conditions and perform high and low temperature tests on the product to understand the performance of the product in this respect. LISUN GDJS series high and low temperature environmental test chamber can achieve this test.

High and Low Temperature Humidity Environmental Test Chamber is according to IEC60068-2-1 (GB/T2423.1) and IEC60068-2-2 (GB/T2423.2), IEC60068-2-78, IEC60598-1, GB/T2423.17, GB/T5170.2, GB/T5170.5.

High and Low Temperature Humidity Chamber

High and Low Temperature Humidity Chamber

Why do lighting fixtures need high and low temperature impact testing?
1. The plastic shell of the lamp cannot withstand the environment, and the plastic shell of the LED is easy to be brittle and damaged under the impact of high and low temperature;

How much impact does high and low temperature chamber on LED Lamps?

The plastic shell of the LED is easy to be brittle and damaged

 

2. The lamp tube burns out under the condition of rapid temperature change;

How much impact does high and low temperature chamber on LED Lamps?

The lamp tube burns out

 

3. The circuit board chip of the lighting lamp is easy to short-circuit under the impact of cold and heat.

How much impact does high and low temperature chamber on LED Lamps?

The circuit board chip is easy to short-circuit

The influence of low temperature on LED lamps
LED lamps are a kind of lighting products composed of a variety of electronic components and structural parts. The performance of semiconductor devices, electrolytic capacitors, etc. will change at low temperatures, so low temperature factors need to be considered when selecting devices.

How much impact does high and low temperature chamber on LED Lamps?

electrolytic capacitor change at low temperatures

1. The influence of low temperature on the switch tube
The density and activity of the switching tube in the low temperature environment will be reduced, and the starting point of the overload protection will also be reduced.

How much impact does high and low temperature chamber on LED Lamps?

The influence of low temperature on the switch tube

2. The influence of low temperature on electrolytic capacitors
2.1. Electrolytic capacitor electrolyte is easy to freeze in a low temperature environment (the electrolyte production process is different, and the ability to withstand low temperatures is greatly different), the capacitance value is reduced, the capacitance effect is lost, and there is no load capacity, which makes the LED drive start abnormally.

How much impact does high and low temperature chamber on LED Lamps?

The influence of low temperature on electrolytic capacitors

2.2. Under working conditions, as the temperature decreases, the ESR equivalent series resistance of the capacitor will increase sharply, and the electrolytic capacitor’s ability to suppress ripple will decrease, and the voltage ripple will increase accordingly.

The high and low temperature test has no fixed standards for the specific temperature of the test, the retention time of high and low temperatures, the time of heating and cooling, and the number of cycles to be measured. The usual temperature is -40 to 150°C, the temperature holding time ranges from 2 hours to 8 hours, the temperature change time is generally within half an hour, and the cycle period ranges from 4 to 20 cycles.

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are GoniophotometerIntegrating SphereSpectroradiometerSurge GeneratorESD SimulatorEMI ReceiverEMC Test EquipmentElectrical Safety TesterEnvironmental ChamberTemperature ChamberClimate ChamberThermal ChamberSalt Spray TestDust Test ChamberWaterproof TestRoHS Test (EDXRF)Glow Wire Test and Needle Flame Test.

Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp:+8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp:+8618917996096

Tags:

Leave a Message

Your email address will not be published. Required fields are marked *

=