LPCE-2 High Precision Spectroradiometer Integrating Sphere System is an integrated platform from LISUN for the comprehensive analysis of light sources. It is available in two configurations: the LPCE-2 (LMS‑9000C) for advanced industrial applications and the LPCE-2 (LMS‑9500C) for scientific-grade requirements. The system features an integrally molded integrating sphere equipped with a specimen mount, offering superior measurement accuracy compared to traditional multi-piece (segmented) integrating spheres. It enables the simultaneous measurement of photometric, colorimetric, spectral, and electrical parameters for various light sources, including LEDs, energy-saving lamps, fluorescent lamps and HID (high-intensity discharge) lamps. The test results comply with both domestic and international lighting standards, making the system ideal for R&D prototyping, quality control on production lines, and third-party laboratory certification testing.
Test Parameters:
• Chromaticity Parameters: Chromaticity coordinates, correlated color temperature (CCT), color ratios, peak wavelength, full width at half maximum (FWHM), dominant wavelength, color purity, color rendering index (CRI), CQS, TM-30-24 (Rf, Rg), spectral distribution, etc.
• Photometric Parameters: Luminous flux, luminous efficacy, radiant power, WPE, EQE, EEI, energy efficiency class, pupillary flux, pupillary flux efficacy, pupillary factor, PAR (for horticultural lighting), PPF, etc.
• Electrical Parameters: Voltage, current, power, power factor, frequency; displacement factor (DF) and harmonics (LS2050)
• LED Luminous Flux Maintenance Testing: Luminous flux vs. time, CCT vs. time, CRI vs. time, power vs. time, power factor vs. time, current vs. time, luminous efficacy vs. time
Standards:
| Standards No. | Standards Name |
| CIE 13.3:1995 | Method of measuring and specifying colour rendering properties of light sources |
| CIE 177:2007 | Colour rendering of white LED light sources |
| CIE 84:1989 | The measurement of luminous flux |
| ANSI C78.377-2024 | Specifications for the chromaticity of solid-state lighting products |
| ANSI IES LM‑79‑24 | Approved Method: Optical and Electrical Measurements of Solid-State Lighting Products |
| ANSI/IES LM-80-21 | Approved Method: Measuring maintenance of light output characteristics of solid-state light sources |
| (EU) 2019/2015 | Ecodesign requirements for light sources and separate control gears |
| GB/T 5702-2019 | 光源显色性评价方法 |
| GB/T 24824-2022 | 普通照明用 LED 模块测试方法 |
Specifications:
| LISUN Model | LPCE‑2 (LMS‑9000C) | LPCE‑2 (LMS‑9500C) |
| System Composition and Specifications: | ||
| CCD Spectroradiometer | LMS-9000C High-End Industrial Grade: Available in VIS, UV-VIS, or VIS-NIR spectral ranges; wavelength accuracy ±0.3 nm; color temperature accuracy ±0.3% | LMS-9500C Scientific Laboratory Grade: Available in VIS, UV-VIS, or VIS-NIR spectral ranges; wavelength accuracy ±0.2 nm; color temperature accuracy ±0.2%; features HAMAMATSU TE-cooling array CCD. |
| Digital Power Meter | LS2050/LS2012: Measures AC/DC voltage, current, power, PF/DF, and harmonics (0–50th order); compliant with the LM-79 standard. | |
| Optical Fiber | CFO-1.5M: low optical loss, 1.5-meter connection between integrating sphere and spectrometer | |
| AC Power Source | LSP‑500VARC/LSP‑1KVAC: Provides a stable and pure sinusoidal output for AC-powered light sources under test. | |
| DC Power Source | DC Series: Provides a stable DC power output for standard lamps, auxiliary lamps, and DC-type light sources under test. | |
| Integrating Sphere | IS-1.5MA/IS-0.3M: features a one-piece molded design and a high-diffuse-reflectance coating; includes a built-in sample stage, auxiliary light source, and a cross-laser alignment system. | |
| Standard Light Source | SLS‑50W/SLS‑10W: traceable to NIM/NIST, for optical calibration of integrating spheres and spectroscopic systems | |
| Auxiliary Lamp | RLS-100W/RLS-50W: Used for self-absorption correction in integrating spheres, compensating for luminous flux deviations caused by light absorption by the sample under test. | |
| 19-inch Standard Cabinet | CASE-19IN: Rack-mount design with integrated cable management and thermal dissipation; provides a unified, organized enclosure for the entire system. | |
| Optional Expansion: Enables ANSI/IES LM-82-20 Testing of Light Source Temperature Characteristics | ||
| Constant Temperature Integrating Sphere |
IS-1.5MT/IS-2.0MT: Temperature-controllable integrating sphere cavity, designed to simulate various ambient temperatures | |
| Multiplex Temperature Tester |
TMP-8/TMP-16: Multi-point synchronous temperature acquisition, used for testing the temperature characteristics of LM-82 light sources | |
| Other specifications: | ||
| Product Datasheet | Please click here for LPCE‑2 (LMS‑9000C) | Please click here for LPCE‑2 (LMS‑9500C) |
| General System Features | Features an integrated auxiliary lamp with built-in self-absorption correction; supports temperature readings from both inside and outside the integrating sphere. | |
| Luminous Flux Calculation Model | Spectroscopic methods, photometric methods, and combined spectroscopic-photometric correction methods | |
| Supporting Software | Software available in Chinese and English; compatible with Win7/Win8/Win10/Win11; export capabilities for spectral curves and PDF/Excel reports. | |
| Applications | Laboratories for R&D, incoming quality inspection, and general testing in small and medium-sized enterprises (SMEs) | Large and medium-sized lighting enterprises, authoritative third-party testing institutions, and scientific research and academic institutions |
LISUN LPCE-2(LMS-9000C) High Precision Spectroradiometer Integrating Sphere System – After-sales Frequently Asked Questions (FAQ).
LISUN LPCE-2(LMS-9000C) High Precision Spectroradiometer Integrating Sphere System were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.
LISUN LPCE-2(LMS-9500C) High Precision Spectroradiometer Integrating Sphere System – After-sales Frequently Asked Questions (FAQ).
LISUN LPCE-2(LMS-9500C) High Precision Spectroradiometer Integrating Sphere System were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.
LISUN LPCE-2(LMS-9000B/A) High Precision Spectroradiometer Integrating Sphere System – After-sales Frequently Asked Questions (FAQ).
LISUN LPCE-2(LMS-9000B/A) High Precision Spectroradiometer Integrating Sphere System were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.
It was an essential product for manufacturing and research. I purchased it after confirming that it is a CIE/IEC certified product. The quality of the product is excellent and the satisfaction with the price is high. Employees are also satisfied with their response to repairs and after-sales services.
LISUN supply the test instruments and solutions for Automotive Electronics. The test solutions...
This customer is a large laboratory from Costa Rica. They purchased a full set of led test equipment from LISUN this...
Invited by customers, Lisun engineer visited India to do training service. These customers are India local famous LED...
Lisun engineer visited four Europe customers this time. Two Spain customers, one UK customer and one Germany...
This Algeria client is a national laboratory. They built a new big building recently for a new lab. And ordered all the...
Our engineer went to Austrilia and Indonisia to install instruments and train them this July. The customer from...
After the work in Turkey, our engineer go to Czech and Spain for the installation and training for the LSG-2000...
This Chile customer is a private organization. They do product certification, laboratory analysis, testing,...
Our engineer went to Malaysia and Indonesia. There were three customers in Malaysia and one customer in Indonesia...
Lisun engineer visited Bulgaria. Our engineer was too busy because there were many customers who purchased Lisun...
Two new Turkey customers ordered Lisun Group’s instruments recently. Our engineer went to Turkey to do the installation...
If you need to disable the 64bit digital signature enforcement of the computer, follow the...
Ultraviolet rays are rays of sunlight with a wavelength of 100 to 400 nanometers (nm). English is...
When LEDs arrived on the market, their tremendous efficiency and money saving potential changed the...
Spectrum is the relative distribution of wavelength and light intensity. The spectrum of LED is...
1. Introduction of flicker parameter Flicker (light source flicker) means that the light output of...
LM-79-19 English Version Free Download: Click Here LM-79-19 Spanish Version Free Download: Click...
Color difference is an important indicator of lighting lamps color performance. Color difference is...
On 5th , December, 2019, the European Commission officially announced the new ErP Regulation (EU)...
Ultraviolet lamps are a type of light source that can produce ultraviolet light with a large...
Fair: HKTDC Hong Kong International Lighting Fair 2019 (Autumn Edition) Date:...