Product No: LSG-1890BCCD
LSG-1800ACCD / LSG-1890BCCD High Precision Rotation Luminaire Goniospectroradiometer employs a testing principle in which the detector remains stationary while the luminaire under test rotates. The system consists of a goniophotometer main unit integrated with a high-precision CCD spectroradiometer. The luminaire can rotate continuously from -180° to +180° along both horizontal and vertical axes, supporting measurement modes in both C-γ (single-arm configuration) and B-β (dual-arm configuration) coordinate systems. The LSG-1890BCCD is equipped with a temperature-stabilized photometric probe, Japanese Mitsubishi servo motors, and high-precision German angle encoders. A laser alignment device ensures that the center of the luminaire coincides with the center of rotation, providing precise angular positioning and guaranteeing high accuracy and repeatability for full-space photometric testing.

High Precision Rotation Luminaire Goniospectroradiometer
LSG-1800ACCD / LSG-1890BCCD High Precision Rotation Luminaire Goniospectroradiometer with spectral distribution measurement capabilities is designed for a wide range of lighting products, including LED luminaires, horticultural lighting, HID lamps, and fluorescent lamps. It is suitable for R&D, performance verification, factory quality control, and third-party compliance testing. The system includes professional testing software (available in both Chinese and English) that supports the export of spectral data and industry-standard photometric file formats (such as IES and LDT). It integrates seamlessly with lighting simulation software like DIALux and enables the measurement of spatial color distribution as well as PAR/PPF/PPFD spatial distribution for horticultural lighting, ensuring compliance with both domestic and international (European and American) standards for integrated photometric and colorimetric testing.
Test Parameters:
• Photometric Parameters: 3D luminous intensity distribution, total luminous flux, luminaire luminous efficacy, EEI (Energy Efficiency Index), beam angle, UGR (Unified Glare Rating), isolux/isocandela curves, utilization factor, BUG (Backlight, Uplight, and Glare) rating, LCS (Luminaire Classification System), upward/downward luminous flux ratio, etc.
• Electrical Parameters: Voltage, current, power, power factor, frequency, and harmonics (LSG-1890BCCD).
• Colorimetric Parameters: Spectral distribution, CIE chromaticity coordinates (x, y) and (u’, v’), CCT (Correlated Color Temperature), Duv, color rendering index (Ra/R1–R15), CQS, IES TM-30-24 (Rf/Rg), dominant wavelength, color purity, melanopic flux, spatial color temperature, and color non-uniformity (Δu’v’). Also includes parameters for horticultural lighting, such as PAR, PPF, and PPFD.
Standards:
| Standards No. | Standards Name |
| IES LM‑79‑24 | Photometric and Electrical Measurements of Solid‑State Lighting Products |
| IES LM‑75‑20 | Goniophotometric Testing of Luminaires |
| CIE 70:1987 | Measurement of absolute luminous‑intensity distributions |
| CIE 121:1996 | The photometry of luminaires |
| EN 13032‑1:2019 | Light & lighting Measurement & presentation of photometric data of lamps and luminaires |
| (EU) 2019/2015 | Ecodesign requirements for luminaires and directional lamps |
| GB/T 9468‑2024 | 灯具分布光度测量的一般要求 |
| GB/T 26184‑2022 | 绝对发光强度分布的测量方法 |
| GB/T 22907‑2022 | 灯具的光度测试和分布光度学 |
| GB/T 7002‑2022 | 投光照明灯具光度测试 |
| GB/T 19658‑2023 | 反射灯中心光强和光束角的测量方法 |
| GB/T 23110‑2022 | 投光灯具光度测试 |
Specifications:
| LISUN Model | LSG-1800ACCD | LSG-1890BCCD |
| Angular Testing Accuracy | 0.2° | 0.1° |
| Measurement Coordinate System | C-γ and B-β dual-mode (EN 13032-1 Clause 6.1.1.3 Type 1 goniophotometer) | |
| Rotation Angle Range | Vertical axis: -180° to +180° (0° to 360°); Horizontal axis: -180° to +180° (0° to 360°) | |
| Illuminance Measurement Range | 0.0001 lx~200k lx | |
| Photometric Probe Class | CIE Class A (visible light 350–800 nm; optional high-precision Class L or other UV photometric probes available —please refer “Optional Configurations” for details) |
|
| System Stray Light | <0.1% | |
| Spectral Test Wavelength Range | 350 nm~800 nm | |
| Chromaticity Coordinate Accuracy | ±0.0015 (under standard light source conditions) | |
| Software System | Available in Chinese and English; compatible with Win7, Win8, Win10, and Win11; supports export to IES, LDT, CIE, TM4, CEN, and Excel formats; supports calculation and export of spatial color data as well as PAR/PPF/PPFD values. | |
| System Configuration Components | Please click here for details. | |
| Max. Size of EUT | Φ1600*600 mm (Diameter * Thickness)、50 kg | Φ2000*600 mm (Diameter * Thickness)、60kg |

LSRF-3 Stroboscopic Performance Test
Optional Configuration 1: The LSG-1800ACCD / LSG-1890BCCD High Precision Rotation Luminaire Goniospectroradiometer can be equipped with a variety of photometric probes. It supports the testing of ultraviolet (UV) light sources as well as high-precision photometric measurement of LEDs, covering the UVA, UVB, UVC, and visible light spectral ranges.
| LISUN Model | PHOTO-UVA-A | PHOTO-UVB-A | PHOTO-UVC-A | PHOTO-VIS-L |
| Wavelength Range | UVA: 320~400nm | UVB: 275~320nm | UVC: 200~275nm | VIS: 350~800nm |
| UV Test Report Sample | UVA Photomectric Report | UVB Photometric Report | UVC Photometric Report | N/A |
| Photo Detector Accuracy | Class A (Made by LISUN) | Class L (Made in Germany) | ||
Optional Configuration 2: The LSG-1800ACCD / LSG-1890BCCD High Precision Rotation Luminaire Goniophotometer can be equipped with the optional LSRF-3 Lamp Start, Run-up Time and Flicker Test System and CLAMP-LSRF test fixture. It fully complies with standards and regulations such as BASIC, ENERGY STAR V2.1, CA CEC, IEC TR 61547-1:2020 (Note: for dynamic Pst-LM(I) flicker testing under this standard, it is recommended to upgrade the standard AC power supply of the LSG-1800ACCD / LSG-1890BCCD to the LSP-500VARC-Pst or LSP-1KVARC-Pst model), CIE TN 006:2016, IEEE Std 1789, EU ErP, SASO 2902-2018, and IEC 60969. It is designed for testing the start-up time, rise time, and flicker performance of light sources, including LEDs and energy-saving lamps.

LSRF-3 Stroboscopic Performance Test

LSRF-3 Test for Lamp Starting, Run-up, and Stabilization
LISUN LSG-1890BCCD High Precision Roation Luminaire Goniospectroradiometer were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.
The product is very good, the service is very professional👍
LISUN's indoor and outdoor LED luminaires and LED fixtures test solutions fully cover key...
Lisun engineer visited four Europe customers this time. Two Spain customers, one UK customer and one Germany...
At the beginning of october 2017, LISUN engineer fly to Brazil immediately after the installation and training in the...
In March 2017, Lisun engineer visited Columbia to do installation and training for our customer who is lad client. The...
This is a big lighting company in Turkey. They purchase a set of LSG-1800BCCD High Precision Rotation Luminaire...
A customer in Croatia bought a LSG-1800BCCD goniospectroradiometer system from LISUN. As soon as they received the...
This Greek client manufacture all sizes luminaires. So they need bigger size goniophotometer. This model LSG-1800XCCD...
At the end of October 2017, LISUN engineer Jacky once again set foot on the journey of installation & training for...
This customer is a relatively well-known manufacturer of various indoor and outdoor lamps in Istanbul of Turkey. It’s...
This customer is the leader in professional and consumer lighting solutions that are sustainable and energy efficient...
This trip to Mexico is mainly to do installation and training for new customers and visit old customers for equipment...
Definition of light intensity: Light intensity is referred to as light intensity. The...
Definition of light distribution curve: It refers to the light intensity distribution of light...
LM-79 and LM-80 are energy efficiency standards approved by IESNA for LED product testing. LM-79...
Spectrum is the relative distribution of wavelength and light intensity. The spectrum of LED is...
As well as we know that for the LED luminaires lumen test, the CIE121: 1996 Clause 6.1, CIE127-2007...
There is a wide range of goniophotometers on sale in the market, including central rotation type,...
The goniophotometer is an instrument that uses spectrophotometry to perform quantitative and...
The main parameters of LED lamps and lanterns include: A: Electric parameters: voltage, current,...
The photometric center of a lamp or luminaire is the reference point, from which the photometric...
According to IESNA-LM-79 standard, Goniophotometer is used for light intensity distribution and...