Product No: LSG-1890B
LSG-1890B / LSG-1800A High Precision Rotation Luminaire Goniophotometer (light distribution curve testing system) employs a testing principle where the photometric probe remains stationary while the luminaire under test rotates. The luminaire can rotate continuously from -180° to +180° along both horizontal and vertical axes, supporting measurement modes for both C-γ (single-arm structure) and B-β (dual-arm structure) coordinate systems. Equipped with a constant-temperature photometric probe, Japanese Mitsubishi servo motors, and a German high-precision angle encoder, the system utilizes a laser alignment device to align the luminaire’s center with the axis of rotation; this ensures precise angular positioning and guarantees high accuracy and repeatability in full-space photometric testing.

High Precision Rotation Luminaire Goniophotometer
LSG-1890B / LSG-1800A high-precision goniophotometer is designed for various general lighting products—including LED luminaires, HID lamps, and fluorescent lights—to meet needs ranging from R&D and performance verification to factory quality control and authoritative third-party testing. It comes with professional testing software (supporting both Chinese and English) and enables the export of standard photometric data files such as IES and LDT. Compatible with lighting simulation software like DIALux, the system meets the standard testing and compliance requirements for lighting products in domestic, European, and American markets.
Test Parameters:
• Photometric parameters: 3D luminous intensity distribution, total luminous flux, luminaire efficacy, EEI, beam angle, UGR (Unified Glare Rating), isolux curves, isocandela curves, utilization factor, BUG rating, LCS (Luminaire Classification System), upward/downward luminous flux ratio, etc.
• Electrical parameters: Voltage, current, power, power factor, frequency, harmonics (LSG-1890B).
Standards:
| Standards No. | Standards Name |
| IES LM‑79‑24 | Photometric and Electrical Measurements of Solid‑State Lighting Products |
| IES LM‑75‑20 | Goniophotometric Testing of Luminaires |
| CIE 70:1987 | Measurement of absolute luminous‑intensity distributions |
| CIE 121:1996 | The photometry of luminaires |
| EN 13032‑1:2019 | Light & lighting Measurement & presentation of photometric data of lamps and luminaires |
| (EU) 2019/2015 | Ecodesign requirements for luminaires and directional lamps |
| GB/T 9468‑2024 | 灯具分布光度测量的一般要求 |
| GB/T 26184‑2022 | 绝对发光强度分布的测量方法 |
| GB/T 22907‑2022 | 灯具的光度测试和分布光度学 |
| GB/T 7002‑2022 | 投光照明灯具光度测试 |
| GB/T 19658‑2023 | 反射灯中心光强和光束角的测量方法 |
| GB/T 23110‑2022 | 投光灯具光度测试 |
Specification:
| LISUN Model | LSG-1800A | LSG-1890B |
| Angular Testing Accuracy | 0.2° | 0.1° |
| Measurement Coordinate System | C-γ and B-β dual-mode (EN 13032-1 Clause 6.1.1.3 Type 1 goniophotometer) | |
| Rotation Angle Range | Vertical axis: -180° to +180° (0° to 360°); Horizontal axis: -180° to +180° (0° to 360°) | |
| Illuminance Measurement Range | 0.0001 lx~200k lx | |
| Photometric Probe Class | CIE Class A (visible light 350–800 nm; optional high-precision Class L or other UV photometric probes available —please refer “Optional Configurations” for details) |
|
| System Stray Light | <0.1% | |
| Software System | Supports Chinese and English; compatible with Windows 7, 8, 10, and 11; supports export to IES, LDT, CIE, TM4, CEN, and Excel formats. | |
| System Configuration Components | Please click here for details. | |
| Max. Size of EUT | Φ1600*600 mm (Diameter * Thickness)、50 kg | Φ2000*600 mm (Diameter * Thickness)、60kg |

LSG-1800A/LSG-1890B Test Size And Weight
Optional Configuration 1: The LSG-1890B / LSG-1800A High Precision Rotation Luminaire Goniophotometer supports a range of optional photometric probes, enabling testing of UV light sources and high-precision LED photometry across UVA, UVB, UVC, and visible light wavebands.
| LISUN Model | PHOTO-UVA-A | PHOTO-UVB-A | PHOTO-UVC-A | PHOTO-VIS-L |
| Wavelength Range | UVA: 320~400nm | UVB: 275~320nm | UVC: 200~275nm | VIS: 350~800nm |
| UV Test Report Sample | UVA Photomectric Report | UVB Photometric Report | UVC Photometric Report | N/A |
| Photo Detector Accuracy | Class A (Made by LISUN) | Class L (Made in Germany) | ||
Optional Configuration 2: The LSG-1800A / LSG-1890B High Precision Rotation Luminaire Goniophotometer can be equipped with the LSRF-3 Lamp Start, Run-up Time and Flicker Test System and CLAMP-LSRF test fixture. This setup fully complies with standards and regulations such as BASIC, ENERGY STAR V2.1, CA CEC, IEC TR 61547-1:2020 (Note: for dynamic Pst-LM(I) flicker testing under this standard, it is recommended to upgrade the standard AC power supply of the LSG-1800A/LSG-1890B to the LSP-500VARC-Pst or LSP-1KVARC-Pst model, CIE TN 006:2016, IEEE Std 1789, EU ErP, SASO 2902-2018, and IEC 60969. It is used to test parameters such as start-up time, rise time, and flicker performance for light sources like LEDs and energy-saving lamps.

LSRF-3 Stroboscopic Performance Test

LSRF-3 Test for Lamp Starting, Run-up, and Stabilization
The types of Goniophotometers can be basically divided into Type A, Type B and Type C. For a detailed description, please refer to the 1987 edition of CIE 70. The difference between them lies in the way the lighting equipment rotates during the measurement and the photometric data obtained during this measurement.
Goniophotometer is a instrument used to measure the light distribution performance of lamps. Goniophotometer measures the spatial light intensity distribution of lamps or light sources, total luminous flux and lamp efficiency and other parameters.
Goniophotometer need to work in larger darkroom. Use low-reflectivity materials in the room to avoid reflected light from entering the photo detector. The goniophotometer tests the illuminance and light intensity of the lamp at all spatial angles to calculate the absolute luminous flux value of the lamp and all other photometric parameters related to the space.
LISUN LSG-1890B High Precision Rotation Luminaire Goniophotometer – After-sales Frequently Asked Questions (FAQ).
LISUN LSG-1890B High Precision Roation Luminaire Goniophotometer were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link.
We have the LSG-1800BCCD gonio photometer. LISUN is professional and the photometer is nice. LISUN engineer came and installed for us. Now everything is functional. We are glad to cooperate with LISUN.
LISUN's indoor and outdoor LED luminaires and LED fixtures test solutions fully cover key...
Lisun engineer visited four Europe customers this time. Two Spain customers, one UK customer and one Germany...
Our engineer went to Austrilia and Indonisia to install instruments and train them this July. The customer from...
After the work in Turkey, our engineer go to Czech and Spain for the installation and training for the LSG-2000...
Lisun engineer visited Bulgaria. Our engineer was too busy because there were many customers who purchased Lisun...
Two new Turkey customers ordered Lisun Group’s instruments recently. Our engineer went to Turkey to do the installation...
Lisun engineer visited Brazil for this laboratory client . This customer is a research and development company, they...
The Brazilian customer found LISUN brand and contacted us when they learned about the LED test instruments on the...
Lisun engineer visited Germany, Romania, Italy and Austria after Germany Frankfurt Lighting & Building Fair in the...
LISUN engineer visited Saudi Arabia to do installation and training recently. He visited two customers this time. They...
This time, our young engineer Joye Yang set off to do installation and training for our customer in Korea. This...
What is the LED test standard? Semiconductor light-emitting diode (LED) is a new type of...
Definition of light intensity: Light intensity is referred to as light intensity. The...
Definition of light distribution curve: It refers to the light intensity distribution of light...
LM-79 and LM-80 are energy efficiency standards approved by IESNA for LED product testing. LM-79...
LM-79-19 English Version Free Download: Click Here LM-79-19 Spanish Version Free Download: Click...
Goniophotometer measures light intensity performance measurement of luminaries and light source,...
Fair: LED Expo New Delhi Date: 2019/11/14-2019/11/16 City: New Delhi Exhibition Hall: India Expo...
Fair: HKTDC Hong Kong International Lighting Fair 2019 (Autumn Edition) Date:...
LISUN can provide very fine Photo Detectors. They are NIM traceable (directly compared with NIM...
LED is not only a semiconductor device, but also a light source. It has the advantage such as high...