LM-79 Moving Detector Goniophotometer (Mirror Type C)
LSG-6000
High Precision Rotation Luminaire Goniophotometer
LSG-1890B
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1890BCCD
Goniophotometer for Automotive and Signal Lamps
LSG-1950
Goniophotometer for Traffic Signal Lamps
LSG-1950S
Compact Goniophotometer
LSG-1200A
Near Field Moving Detector Goniophotometer
LSG-1900B
Select an organization
to browse standards
The U.S.A. Energy Star newest standard IES LM-79-19 had issued in 2019 year. LISUN engineer depts already public the Article: How the difference between the LM-79-19 and LM-79-08, the more details please click here. You also can download the LM-79-19 English version standard here.
LISUN supply the Integrating Sphere & Spectroradiometer System, Goniophtometer System and LED Optical Maintenance System to meet the LM-79-19, LM-80, LM-82 and TM-21
Integrating Sphere and Spectroradiometer Test System is for single LEDs and LED lighting products light measurement. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to IES LM-79-19, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products.
Measures:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, PAR and PPF
• Electrical: Voltage, Current, Power, Power Factor (Option: VF, IF, VR, IR), Harmonic (Only LS2010 can test harmonic)
• LED optical maintenance test: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.
The LSG-5000 is fully meet LM-79-19 request. The LSG-1800B is an B-Beta and C-Gamma goniophotometer. The LSG-1800BCCD is a kind of goniospectroradiometer which has the Integrating sphere and goniophotometer functions. The LSG-1200A is only used to test the lamps which diameter is less than 180mm and beam angle is less than 180degree.
The LEDLM-80PL LED Optical Aging Test Instrument system is fully meet LM-80, LM-82 and TM-21 request. Some of the manufactory we advise to use SY2036 Aging and Life Test Rack with LPCE-2 (LMS-9000) to do an alternative test.
In 2026, the Bureau of Indian Standards (BIS) completed and issued the revised standard IS 16102-2:2026 for the operational performance of outdoor LED lighting equipment. As...
Abstract Light-Emitting Diode (LED), as a new generation of solid-state lighting source, is widely used in various fields due to its advantages of high efficiency, energy...
The life of LED is still a characteristic of long -term attention. The theoretical life of LED is very long. Like the traditional light source uses...
Semiconductor Solid Lighting (SSL) is a trend of future development, especially today, where global energy is becoming increasingly tense and the climate is deteriorating today. With...
SY2036 LED aging and life test rack is fully designed according to the IEC standards, and it can also be designed based on the customer request....
The LSG-1200A compact goniophotometer is used to measure the luminous intensity distribution curve, intensity data, beam angle and other photometric parameters for Chip LED, LED Module, LED Spotlight...
LEDLM-80PL LED Lumen Maintenance and Aging Life Test System is designed according to IES-LM-80 and TM-21, it used to test & record the optical and electrical Maintenance for single...
To test and record the optical and electrical maintenance for a single LED or LED module, the LEDLM-80PL System for Testing LED Lumen Aging and Maintenance...
It’s important to run testing on LED aging. Without an aging test, it is impossible to ensure the product’s quality, and unreliable elements will show up...
The potential and advantages of LEDs continue to develop. The next five to fifteen years will be a period of development of LED lighting from traditional...
The goniophotometer is an instrument that uses spectrophotometry to perform quantitative and qualitative analysis of substances. It is mainly used for the measurement of the light...
Goniophotometer is the main measurement equipment for the light distribution performance test of lamps and luminous. It can be used to measure the spatial light intensity...
On 5th, December, 2019, the European Commission officially announced the new ErP Regulation (EU) 2019/2020 and Energy Efficiency Labelling Regulation (EU) 2019/2015 for lighting products, which will...
IESNA Illuminating Engineering Society of North America and ANSI American National Standards Institute jointly issued ANSI/IES LM-80-15 IES Approved Method On June 26, 2015: Measuring Luminous...
LISUN will irregularly update the software of LSG-1800BCCD/LSG-1700BCCD/LSG-5000CCD. However, since each spectroradiometer in the system has its own independent hardware data file, we need to back...
LED lamp aging test standards: Generally speaking, as a green energy-saving LED lamp, if the performance test is reduced before use, there will be a certain...
Recently Saudi Arabia released new LED standard SASO 2902 for energy efficiency, functionality and labeling requirements for Lighting products. We have got the SASO 2902 in 2017 which is draft...
LISUN engineer went to Egypt in December 2018 to provide on-site installation & training services for customers there. During the period, we held a lighting testing...
LISUN engineer went to Iran in December 2018 to provide on-site installation & training services for customers there. And held Lighting Testing Technology Salon on 25th...
LISUN engineer went to Saudi in December 2018 to provide on-site installation & training services for customers there. During the period, we held a lighting testing...
In optical testing, the measurement of luminous flux and color temperature are essential. There are two test equipment for the measurement: Integrating Sphere Testing System and Goniophotometer. Here we...
The main parameters of LED lamps and lanterns include: A: Electric parameters: voltage, current, lamp power, power factor, harmonic, etc B: Colorimetric parameters: correlated color temperature,...
LED package is mainly to provide a platform for LED chips, so that LED chips have better performance of light, electricity and heat. Good packaging can...
LED has the features of long time. According to different power drivers and use conditions, the life of LED can be up to 50,000 hours or...
In general, LED can be used for more than 50000 hours, and some manufacturers are promoting their LED to operate for about 100000 hours. The main...
Use Integrating Sphere Spectroradiometer System to test color parameters for light source and luminaries and use Goniophotometer System to test luminous intensity, which is the measurement...
On January 31, 2018, Lighting Poland 2018 arrived on schedule. LISUN has already prepared well for this exhibition. Our booth address is Hall 4 Booth C25...
IES LM-79-08 Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products. IES LM-79 standard is mainly for photoelectric performance measurement. Generally it is for whole...
Definition: Means luminaries or light sources emit light intensity distribution in space. It can record the luminous flux of luminaries, light quantity, power, power factor, the...
According to IESNA-LM-79 standard, Goniophotometer is used for light intensity distribution and flux test. Accordingly, Lisun Group is goniophotometer manufacture introduced several different types Goniophotometer, the...
IESNA-LM-80 (Measuring Lumen Maintenance of LED Light sources) is an approved method by Lighting Engineering Association of North America (IESNA) for the third generation SSL products;...
The lighting industry practitioners must be familiar with IES file. Firstly introduce IES, IES is short for Illuminating Engineering Society of North America. I.E.S is founded...
LED has the features of long life, but with the different working condition and drive current, its life will be different, but generally the life will...
Nowadays, there are two main categories of LED light sources classified according the forms on the market, one is COB integrated light source directly combined of...
CIE has recently published the first international measurement standard for LED Lamps, LED Luminaires and LED Modules, ie. CIE S025(http://div2.cie.co.at/?i_ca_id=563). CIE Division 2 will present a...
As well as we know that for the LED luminaires lumen test, the CIE121: 1996 Clause 6.1, CIE127-2007 Clause 6.2 and IES-LM-79-08 Clause 9.0 are mentioned...
USA Environmental Protection Agency(EPA) and Department of Energy(DOE) successively released Energy Star and Lighting Facts Standards for LED Luminaires/Bulb from 2010, which makes relevant industry persons...
The U.S. Government issued her LED test standards IESNA-LM-79-08. This approved method is a guide developed for the measurement of Solid State Lighting (SSL) products such as LED...

中文简体