Product No: RFCI61000-6
The RFCI61000-6 series RF Conducted Immunity Test System is used to simulate conducted interference signals induced by radio frequency (RF) fields. These signals are injected into the power and signal lines of the equipment under test (EUT) using standardized injection methods (CDN, electromagnetic clamp, and current clamp). This method evaluates the EUT’s operational stability in the presence of such conducted RF interference.
The RFCI61000-6 series Conducted RF Immunity Testing System innovatively integrates three core modules: a signal source, power amplifier and power meter. It is also compatible with LISUN’s full range of coupling-decoupling networks (CDN), electromagnetic injection clamps and current injection clamps, providing flexible adaptation to the testing needs of different EUT types. It equipped with a large Android touch screen display with English and Chinese support, the system is widely used for EMC compliance testing in a variety of fields, including LED lighting, medical, power, industrial control, new energy charging stations and communications.
Standards:
| Standards NO. | Standards Name |
| IEC 61000-4-6:2023 | Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields |
| EN 61000-4-6:2023 | Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields |
| GB/T 17626.6-2017 | 电磁兼容 试验和测量技术 射频场感应的传导骚扰抗扰度 |
| GJB 151B-2013 | 军用设备和分系统电磁兼容性要求(含 CS114 射频传导抗扰度测试条款) |
Specifications:
| Parameters | LISUN Model | RFCI61000-6-35W | RFCI61000-6-85W |
| 1. Output performance | Output frequency range | 150kHz~230MHz | 150kHz~230MHz |
| Output power | 35W | 85W | |
| Output voltage (CDN method) | 1~17Vrms | 1~30Vrms | |
| Output voltage (electromagnetic clamp method) | 1~11Vrms | 1~18Vrms | |
| Output voltage (current clamp method) | N/A | 1~10Vrms | |
| Output impedance | 50Ω(±5%) | ||
| Voltage Standing Wave Ratio (VSWR) | ≤1.2 | ||
| 2. Built-in signal source | Harmonic suppression | <15dBc | |
| Frequency range | 9kHz~1GHz | ||
| Output Level | -60~10dBm | ||
| Signal Type | Continuous Wave (CW) | ||
| Amplitude Modulation | Modulation frequency 1Hz~10kHz, modulation depth 1%~99% | ||
| 3. Built-in power amplifier | Pulse modulation | Modulation frequency 1Hz~1kHz, duty cycle 1%~100% | |
| Maximum output power | +44dBm(35W) | +49dBm(85W) | |
| 4. Built-in power meter | Operating frequency range | 150kHz~230MHz | |
| Input frequency range | 9kHz~3GHz | ||
| Input power range | -40dBm~+30dBm | ||
Instructions:
Please refer to Figure 20 of Section 7.4.2 of IEC 61000-4-6:2023 or GB/T 17626.6-2017 to select the following injection method: CDN method, electromagnetic clamp method, or current clamp method.

Figure 20 – Rules for selecting the injection method
Recommendation 1:
The RFCI61000-6 series can be used with the following LISUN CDN coupling and decoupling networks to perform CDN injection testing on the EUT:

CDN for RF Conducted Immunity Test
| CDN Types | LISUN Model | Test Ports | Power |
| Power Cables | CDN-M1-16 | Single -phase single-wire power cable | 220V/16A |
| CDN-M1-32 | Single -phase single-wire power cable | 220V/32A | |
| CDN-M2-16 | Single -phase two-wire power cable | 220V/16A | |
| CDN-M2-32 | Single -phase two-wire power cable | 220V/32A | |
| CDN-M2-100 | Single -phase two-wire power cable | 220V/100A | |
| CDN-M3-16 | Single -phase three-wire power cable | 220V/16A | |
| CDN-M3-32 | Single -phase three-wire power cable | 220V/32A | |
| CDN-M3-100 | Single -phase three-wire power cable | 220V/100A | |
| CDN-M3-32-3 | Three -phase and three-wire power cable (3L) | 380V/32A | |
| CDN-M4-32 | Three -phase and four-wire power cable (3L/1N) | 380V/32A | |
| CDN-M4-100 | Three -phase and four-wire power cable (3L/1N) | 380V/100A | |
| CDN-M4-32-PE | Three -phase and four-wire power cable (3L/1PE) | 380V/32A | |
| CDN-M5-32 | Three -phase and five-wire power cable (3L/1N/1PE) | 380V/32A | |
| CDN-M5-100 | Three -phase and five-wire power cable (3L/1N/1PE) | 380V/100A | |
| Non shielding symmetrical lines | CDN-T2 | 2 line | 100V/5A |
| CDN-T4 | 4 line | 100V/5A | |
| CDN-T8 | 8 line | 100V/5A | |
| Non-shielding non-symmetrical lines | CDN-AF2 | 2 line | 100V/5A |
| CDN-AF4 | 4 line | 100V/5A | |
| CDN-AF8 | 8 line | 100V/5A | |
| Shielding lines | CDN-S8 | 2 line、4 line、8 line | 100V/5A |
| CDN calibration jig | CDN-CS100 | It contains 150Ω-50Ω adapter resistance and If you equipped with 1 set of or more sets of CDN, you need to be equipped with at least 1 set of CDN-CS100 (various CDNs can equipped with it) | |
Recommendation 2:
The RFCI61000-6 series can be used with the LISUN AB-EM electromagnetic injection clamp to perform electromagnetic injection testing on the EUT.

AB-EM Electromagnetic Clamp for RF Conducted Immunity Test
• Injection power: Maximum 100W (5 minutes)
• Injection frequency: 150kHz~400MHz
• Coupling/decoupling directivity: Greater than 10dB (>10MHz)
Recommendation 3:
The RFCI61000-6 series can be used with the LISUN AB-100W current injection clamp to test signal lines of any specifications.

AB-100W Current Injection Clamp for RF Conducted Immunity Test
• Supports testing of any signal cable specification: unshielded balanced cables (T2, T4, T8), unshielded unbalanced cables (AF2, AF4, AF8), communication cables (RJ11, RJ11S, RJ45, RJ45S, USB-C, USB-P), and any other cable specification
• Maximum supported cable diameter: 40mm
• Maximum output power: 100W
• Frequency range: 100kHz to 300MHz
• Insertion loss: <7dB
• Includes standard current clamp calibration kits