+8618117273997weixin
EnglishEnglish
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語

REQUEST A QUOTE

=

Triple Loop Antenna | Van Veen Three Loop Antenna

Product No: VVLA-30M

  • Specifications
  • Videos
  • Downloads
  • Applications
  • Standards
  • Installations
  • Tech Articles
  • The VVLA-30M Triple Loop Antenna (also called Van Veen Three Loop Antenna) is used for magnetic field radiated interference testing in the 9kHz~30MHz frequency band. Equipped with a 50Ω/BNC universal interface, it can be used with LISUN EMI-9K series EMI Receivers and is also compatible with mainstream EMI test receivers of the same specifications on the market. For details on LISUN’s new triple-loop antenna design, please click here: This product adopts a screwless quick-installation structure, making assembly and debugging convenient. It comes standard with a height-adjustable and expandable test platform (maximum load 50kg), eliminating the need for an additional test table. The X/Y/Z three-axis orthogonal design enables full-angle testing without displacement, effectively avoiding displacement errors. It is professionally calibrated before leaving the factory, and the antenna integrates a self-calibrating mechanism. This product is used for EMC compliance testing of electrical lighting and similar equipment, VVLA-30M Triple Loop Antenna was recommend to be used in the LISUN SDR-5000B RF Shielding Room or AC-3M Semi-Anechoic Chamber.

    Standards:

    Standards No. Standards Names
    CISPR 16-1-4:2019 Specification for radio disturbance and immunity measuring apparatus and methods – Part 1-4: Radio disturbance and immunity measuring apparatus – Antennas and test sites for radiated disturbance measurements
    CISPR 15:2018 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
    EN 55015:2019 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
    GB/T 6113.104-2023 无线电骚扰和抗扰度测量设备和测量方法 第 1-4 部分:无线电骚扰和抗扰度测量设备 辐射骚扰测量用天线和试验场地
    GB 17743-2021 电气照明和类似设备的无线电骚扰特性的限值和测量方法

    Specifications:

    LISUN Model VVLA-30M VVLA-30MA
    Frequency Range 9KHz ~ 30MHz
    Test Dimensions The X/Y/Z three-axis planes can be freely switched
    Current Probe Coefficient 0dB
    Interface Connetor 50Ω/N Type
    Ring diameter 2m 3m
    After Assembly Size ∅2100*2550mm (Diameter*Height) ∅3200*3750mm
    Packaging Size 2000*400*400mm (L*W*H) 2500*400*400mm
    Packaging Weight 40kg 60kg
    Calibration Method Factory-calibrated (ISO17025 third-party calibration report optional) + Built-in calibration antenna
    Matching Platform Integrated height-adjustable and expandable platform, maximum load capacity 50kg
    Core Functions Magnetic field radiation interference detection, supporting compliance testing for lighting products.

    Note: The LISUN LS-LNA09K1000 preamplifier is optional and is mainly used to amplify weak electromagnetic signals so that test instruments (such as the LISUN SPA-3P6G Spectrum Analyzer or the LISUN EMI-9K series EMI Receivers) can more accurately detect and analyze these signals. EMC testing aims to evaluate the device’s immunity to electromagnetic interference and the level of electromagnetic interference it generates, and the preamplifier plays a crucial role in this process.

    LS-LNA09K1000 preamplifier

    LS-LNA09K1000 preamplifier

    Specifications:

    Operating frequency 9kHz~1GHz
    Noise Figure 2.5dB
    Impedance 50Ω
    Gain >30dB
    Interface Type N type
    Tags: , ,
  • Calibrate Certificate

    Standards

  • Mobile and Network Test Solutions

    LISUN's mobile and network test solutions include EMC/EMI testing, color glossiness measurement, IP...

  • IEC 62052-11:2003 specifies general requirements, tests, and test conditions for AC electricity metering equipment. It covers aspects such as functionality, mechanical structure, electrical...
  • Denmark – Installation and training for Goniophotometer, Integrating Sphere System amd EMI test equipment

    18 May, 2019

    This Danish customer is a testing institution. They purchased LSG-1700B Rotation Luminaire Goniophotometer (Big...

    Famous EMI/EMC equipment agent collaborates with LISUN to successfully purchase the VVLA-30M Three Loop Antenna.

    10 Feb, 2024

    In recent years, the growing demand for electromagnetic compatibility (EMC) testing has played a crucial role in the...

    Vietnam – LISUN Engineer Provide Installation and Training for Three Loop Antenna and UV Aging Test Chamber

    20 Dec, 2025

    The customer in this case holds an important position in the lighting and home appliance sectors in Vietnam. With a...

  • The Main Differences Between Lighting test Standard CISPR 15: 2018 and 2013 Versions

    03 Dec, 2019

    There are many customers feedback that their LED luminaires can't pass CE Certificate EMI Radiation...

    CISPR15 Three Loop Antenna Function Introduction

    15 Jan, 2017

    The three loop antenna are often used during electromagnetic radiation test. Lisun three loop...

    Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

    04 Jan, 2017

    Standards GB17743-2007 / CISPR 15:2005 <Limits and methods of measurement of radio disturbance...

    What is EMC and What equipment do you need if you want to do EMC test?

    06 Mar, 2017

    With the widespread use of electrical and electronic equipment, the problem of electromagnetic...

    The Triple-Loop Antenna: A Detailed Overview of LISUN VVLA-30M Three Loop Antenna for EMI/EMC Testing

    09 Jan, 2025

    Introduction In the field of electromagnetic interference (EMI) and electromagnetic compatibility...

    Application and Analysis of Three Loop Antenna in Electromagnetic Interference and Compatibility Testing

    23 Apr, 2025

    Introduction In the design and manufacturing of modern electronic devices, electromagnetic...