Portable Spectrophotometer

Product No: HSCD-680/HSCD-700/HSCD-710/HSCD-750/HSCD-760

  • Description
  • Download
  • Inquiry

Brief Introduction

  • Our device adopts internationally agreed observe condition D/8 (Diffused lighting, 8 degrees observe angle) and SCI (specular reflection included)/SCE (specular reflection excluded).
  • Camera view to catch the testing area
  • Uses CLEDs light source – spectrally balanced LED light source
  • ETC Every Time calibration technology
  • Matching color analysis software
  • Automatic gloss compensation technology
  • Innovative light splitting SCS optical engine
  • The most complete and color indicators compares with similar instruments.


Technical Data

TypeHSCD-680HSCD-700HSCD-710HSCD-750HSCD-760
Measurement conditionObservation angle: 2°/10°

Illumination: d/8 (Diffused lighting, 8 degrees observe angle)、SCI (specular reflection included)/SCE (specular reflection excluded) simultaneous measurement. (conform to CIE No.15、ISO 7724/1、ASTM E1164、DIN 5033 Teil7、 JIS Z8722 Condition c standards)

Size of integrating sphereΦ40mm, Avian diffused reflection surface coating
Illumination Light sourceCLEDs (Full band balanced LED light source)Pulse Xenon LampCLEDs (Full band balanced LED light source)
Sensordual light path sensor array
Wavelength Range400-700nm360-740nm400-700nm
Wavelength interval10nm
Half spectral width5nm
Reflectivity range0-200%
Reflectivity resolution0.01%
Measurement light sourceA, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL83, TL84, NBF, U30, CWF
Data being displayedSPD distribution/data, sample’s color values, color difference values/graph, pass/fail results, color error tendency, color simulation,display measurement area, history data color simulation, manual input standard sample, generate measurement report
Measurement time interval2 seconds
Measurement time2S0.5S2S0.5S
Color spaceCIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, ReflectiveCIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflective, Hunterlab, Munsell MI, CMYK, RGB, HSB
Color difference formulasΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*94, ΔE*00ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*94, ΔE*00, ΔEab (Hunter)
Other colorimetric indicesWI (ASTM E313-10, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby); YI (ASTM D1925, ASTM E313-00, ASTM E313-73); Tint (ASTM E313, CIE, Ganz)

Metamerism index Milm, Stick color fastness, Color fastness

ISO luminance, 8 gloss, A density, T density, M density, E density
Repeatabilitylight splitting reflectivity: standard deviation within 0.08%
Color values: ΔE*ab <=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),

Maximum: 0.05

color values; ΔE*ab <=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),

Maximum: 0.05

color values: ΔE*ab <=0.02, Maximum: 0.04Chromaticity values: ΔE*ab <=0.015

Maximum: 0.03

Battery capacityrechargeable, 10000 continuous tests, 7.4V/6000mAh
InterfaceUSB
Data storage20000 test results
Light source longevity5 years, 1.5 million tests
Inter-instrument agreementΔE*ab within 0.2 (BCRA color charts II, average of the 12 charts)
Size181*73*112mm (L*W*H)
Weightabout 550g (does not include battery’s weight)
DisplayTrue color screen that includes all colors
Work temperature range0~45℃, relative humidity 80% or below (at 35°C ), no condensation
Storage temperature range-25℃ to 55℃, relative humidity 80% or below (at 35°C ), no condensation
Standard accessoriesDC adapter, Lithium battery, manual, color management software, drive software, electronic manual, color management guide, USB cable, black/white calibration tube, protective cover, spire lamella, portable bag, electronic color charts, measurement and test report
Optionalpowder molding device, micro printer
Color matching systemnot matchmatch
UV light sourcewithout UV light sourceWith UV light sourcewithout UV light source