+8618117273997weixin
EnglishEnglish
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語

REQUEST A QUOTE

=

Adjustable Reference Standard Ballast

Product No: DYJ

  • Specifications
  • Downloads
  • Applications
  • Standards
  • Installations
  • Tech Articles
  • According to Double-ended fluorescent lamp of IEC 60081 (GB/T10682) and the single-ended fluorescent lamp of IEC60901 (GB/T17262), ANSI C78.81 and ANSI C82.3, DYJ Adjustable Reference Standard Ballast is used to test for 4w~85w fluorescent lamp and electronic ballast.

    Standard:
    IEC 60081 (GB/T10682) “Double-capped fluorescent lamps – Performance specification”
    IEC60901 (GB/T17262) “Single-Capped Fluorescent Lamps – Performance Requirements”
    ANSI C78.81 “American National Standard for electric lamps – Specifications for the Chormaticity of Solid State Lighting Products”
    ANSI C82.3 “Specifications for Fluorescent Lamp Reference Ballasts”
    IEC60188  “High-pressure mercury vapour lamps – Performance specifications”
    IEC60662 “High Pressure sodium vapour lamps – Performance Specifications”

    Specification:
    • Inductance: 0~1240Ω (adjustable)
    • Inductance Power Factor COSφ: 0.075~0.120
    • Resistance: 0~111Ω (adjustable)
    • Current Range 0.150~0.670A (Imax: 1A)
    • Order Code: DYJ-50HZ is for 50Hz lamp test and DYJ-60HZ is for all 60Hz lamp test

    According to IEC60188, IEC60662 and ANSI C82.5, Lisun Group developed the DYJ-HID Standard Ballast (Reference Ballast) to test the HID lamp, HID ballast, High-Voltage Mercury Lamp, High Voltage Sodium Lamp, Metal Halide Lamp and Halide Reactor. Please contact us for more information.

    LISUN DYJ-60HZ Adjustable Reference Standard Ballast – After-sales Frequently Asked Questions (FAQ)
    LISUN DYJ-60HZ Adjustable Reference Standard Ballast were in the market for more than 10 years, LISUN engineers service team already summary the most of the After Sales Questions and Answers in the above link. Please read it carefuly, you can solve the most of the problems by yourself if you have some questions while using the instruments. LISUN will be continue to update this pages and more FAQ can be found in this topic link. 

    Tags: , , , ,
  • Calibrate Certificate

    Standards

  • HID Lamp Test Solutions

    For the HID Lamp design and manufactory, LISUN can supply a full quality control test solution.

    Fluorescent Lamp Test Solutions

    For the Fluorescent Lamp design and manufactory, LISUN can supply a full quality control test...

  • IEC 60662:2002 is an international standard that specifies performance requirements for high-pressure sodium vapor lamps used in general lighting. This standard outlines technical specifications,...
    ANSI/IES LM-41-20 Photometric Testing of Indoor Fluorescent Luminaires need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test
    CIE 70-1987 The Measurment of Absolute Luminous Intensity Distributions need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test
    CIE 043-1979 Photometry of floodlights need to use LISUN goniophotometer, integrating sphere and spectroradiometer system to test
  • Chile – Provide installation and training for the customer who purchased integrating sphere and Spectroradiometer,ect from LISUN

    13 May, 2016

    This Chile customer is a private organization. They do product certification, laboratory analysis, testing,...

    Ecuador – Install IP waterproof dustproof test chamber, temperature humidity chamber and IK level test

    21 Apr, 2016

    After installation and training in Mexico, our engineers went to next station, Ecuador. This customer is Ecuador...

    Japan – Installation and training for customer who purchased DYJ Adjustable Reference Ballast From Lisun

    29 Dec, 2015

    Lisun Electronics Inc. has received an order for DYJ (Adjustable Reference Ballast) from Japan, which means Lisun...

    Morocco- Install LPCE-2 Spectroradiometer Integrating Sphere System and DYJ Adjustable Reference Ballast

    05 Jan, 2017

    Lisun engineer visited Morocco customer who is a laboratory. This customer purchased LPCE-2(LMS-9000A)...

  • Difference between Electronic Ballast and Inductive Ballast

    14 Jul, 2016

    The ballast (resistor ballast) is a device for limiting the flow of sunlight and generating...

    LISUN DYJ Adjustable Reference Standard Ballast – After-sales Frequently Asked Questions (FAQ)

    01 Jun, 2023

    According to Double end fluorescent lamp of IEC 60081 (GB/T10682) and the single-ended fluorescent...