27 Nov, 2026 2 Views Author: Cherry Shen

Research on LED Photometric, Colorimetric and Electrical Testing Method Based on Goniophotometer vs Integrating Sphere

Abstract:

The optical performance evaluation of LED lighting products relies on two complementary datasets: full-space luminous intensity distribution and total luminous flux. Taking the LISUN LSG-6000 LM-79 Moving Detector Goniophotometer (Mirror Type C) and LPCE-2 (LMS-9000C) High Precision Spectroradiometer Integrating Sphere System as research objects, this paper analyzes the measurement principles, key specifications and standard compliance of the two instruments, and proposes a collaborative testing workflow of “rapid screening via integrating sphere — precise characterization via goniophotometer”. The results show that the two systems complement each other in total luminous flux/color fast measurement and three-dimensional luminous intensity distribution measurement respectively. Combined application can fully meet the photometric, colorimetric and electrical parameter test requirements specified in LM-79, providing an executable solution for R&D of lighting manufacturers and third-party laboratories.

1. Introduction

The optical performance of LED luminaires cannot be summarized by a single indicator. Total luminous flux and luminous efficacy reflect its energy conversion efficiency, while three-dimensional luminous intensity distribution determines the spot profile, illumination coverage, glare level and illuminance uniformity, which serves as the raw data for optical simulation in lighting design software. Standards including IES LM-79-24, EN 13032-1:2019 and CIE S025 require solid-state lighting products to deliver complete photometric, colorimetric and electrical test results, with exportable IES and LDT standard photometric files. In conventional testing, the integrating sphere measures the total quantity, while the goniophotometer captures spatial distribution. Separate operation of the two instruments may lead to inconsistent data benchmarks, repeated fixture setup and long testing cycles. This paper focuses on the cooperation mode of the two flagship instruments from LISUN.

2. Goniophotometer: Full-space Luminous Intensity Distribution Measurement of LSG-6000

The LSG-6000 is a C-γ goniophotometer of rotating mirror type defined in Clause 6.1.1.3 (Type 4) of EN 13032-1. It adopts the configuration where the luminaire remains stationary while the detector and reflector rotate synchronously. The engineering advantage of this design is that the DUT (device under test) keeps static throughout the test, avoiding thermal drift and posture deviation generated by rotation of medium-high power luminaires, so that the burning condition remains stable. This feature is especially critical for HID lamps and high-power street light testing.

Key technical specifications: γ scanning range ±180° (or 0~360°), angular accuracy 0.05°, angular resolution 0.001°; standard equipped German Class L thermostatic photometric detector complying with DIN 5032-6 and CIE Pub. No.69, f1′<1.5%; illuminance measurement range 0.0001 lx ~ 200 000 lx; measurable power up to 600 V/10 A (AC/DC); test distance customizable from 5 m to 30 m according to darkroom layout. The system is equipped with Mitsubishi servo motors and German angle encoders, and cross laser is used for photometric center alignment, which corresponds to the photometric center positioning requirement newly added in LM-79-24.

Four variants are available according to luminaire dimensions: LSG-6000S (Φ1200×500 mm, 40 kg, darkroom height 3.0 m), LSG-6000 (Φ1600×600 mm, 50 kg, 4.1 m), LSG-6000B (Φ1800×800 mm, 60 kg, 4.7 m), LSG-6000L (Φ2000×900 mm, 80 kg, 5.2 m). Output parameters cover luminous intensity distribution, zonal luminous flux, luminaire efficiency, utilization factor, luminance limit curve, UGR glare rating, maximum spacing-height ratio, iso-illuminance diagram, up flux / down flux, effective beam angle, EEI, etc. Test results can be exported in IES, LDT, CIE, TM4 formats and imported directly into DIALux and other lighting software. After upgrading with a CCD spectral module, it becomes LSG-6000CCD, supporting spatial correlated color temperature distribution, as well as PAR, PPF and PPFD distribution testing for horticultural lighting.

LM-79 Moving Detector Goniophotometer (Mirror Type C)

LM-79 Moving Detector Goniophotometer (Mirror Type C)

3. Integrating Sphere System: Luminous Flux and Color Measurement of LPCE-2 (LMS-9000C)

The LPCE-2 takes the LMS-9000C high-precision CCD spectroradiometer as the core, and consists of an integrally formed integrating sphere, digital electrical parameter tester, AC/DC power supply and standard light source to form a complete test chain. The LMS-9000C adopts holographic grating, flat-field correction, electronic shutter control and NIST stray light correction technology. Main specifications: wavelength range 350~800 nm (optional 200~800 nm, 350~1050 nm), wavelength accuracy ±0.3 nm, wavelength repeatability ±0.1 nm; chromaticity coordinate accuracy ±0.002 under Standard Illuminant A; correlated color temperature range 1500~100 000 K, accuracy ±0.3%; CRI accuracy ±(0.3%rd±0.3); photometric linearity ±0.3%; stray light <0.015% @600 nm, <0.03% @435 nm; integration time 0.1 ms~20 s, single measurement within millisecond level with laboratory-grade precision.

The integrating sphere has eight optional sizes from Φ0.3 m to Φ3.0 m. The inner wall is coated with barium sulfate complying with CIE Pub. No.84, with reflectance ρ(λ)≥0.96 at 450~800 nm and ≥0.92 at 380~450 nm. Compared with conventional spliced spheres, the new integrally formed structure reduces light leakage at seams. The sample holder supports maximum load of 20 kg, and four built-in power wires can withstand 5 kW. The platform is adjustable in height and orientation, solving the fixing difficulty of 4π testing for LED street lights and other complete luminaires with high self-absorption. For high-power products with obvious self-absorption effect, the system is equipped with RLS-50W / RLS-100W auxiliary lamps for self-absorption correction, and SLS series standard light sources traceable to NIM for spectral and luminous flux calibration.

Luminous flux measurement supports three modes: spectral method, photometric method and combined method. It synchronously outputs chromaticity coordinates, correlated color temperature, Duv, Ra/R1~R15, CQS, TM-30 (Rf/Rg), peak wavelength, color purity, together with voltage, current, power, power factor and harmonic parameters. It also supports long-term luminous flux maintenance monitoring for LM-80. The system conforms to CIE 177, CIE 13.3, CIE 84, ANSI C78.377, GB/T 24824, LM-79, LM-80 and (EU) 2019/2015.

4. Collaborative Testing Workflow of the Two Instruments

The two devices are not substitutes for each other, but undertake different measurement dimensions. The integrating sphere integrates signals in a uniform light field to obtain total luminous flux and average chromaticity of all directions, featuring fast speed and good repeatability, suitable for production line full inspection and photometric-color-electrical joint tuning in R&D stage. The goniophotometer collects data angle by angle to obtain the spatial function of luminous intensity. Total luminous flux can be further integrated from angular data, and engineering parameters such as glare and iso-illuminance maps can be derived. Since the integrated value obtained by the integrating sphere can also be back-calculated from angular data of the goniophotometer, they can be used for mutual verification. If the total luminous flux deviation of the same luminaire measured by the two instruments exceeds ±2%, it indicates possible abnormality in fixture mounting, self-absorption correction or calibration.

The recommended test sequence is as follows: first complete warm-up stabilization, preliminary luminous flux & chromaticity test and electrical parameter recording on LPCE-2 to screen qualified samples; then transfer the sample to the darkroom of LSG-6000, select the proper model and test distance according to luminaire size, carry out C-γ full-space scanning and export IES/LDT files for optical design validation. For products requiring consistent spatial chromaticity (such as large panel lights and horticultural lighting), LSG-6000CCD can be adopted directly or share calibration data with the CCD module of LPCE-2 to avoid benchmark deviation between two chromaticity systems. The whole procedure covers all LM-79 requirements for total luminous flux, luminous efficacy, luminous intensity distribution, chromaticity coordinates, correlated color temperature, CRI and electrical parameters.

LPCE-2(LMS-9000)High Precision Spectroradiometer Integrated Sphere System

LPCE-2(LMS-9000)High Precision Spectroradiometer Integrated Sphere System

5. Conclusion

With stationary-luminaire C-γ architecture, 0.05° angular accuracy and Class L detector, the LSG-6000 provides reliable three-dimensional luminous intensity distribution data for LED, HID, street lights, floodlights and horticultural lighting products. The LPCE-2 (LMS-9000C) realizes millisecond-level synchronous photometric, colorimetric and electrical measurement relying on integrally formed integrating sphere and high-precision CCD spectroradiometer. The collaborative application balances efficiency of total quantity measurement and integrity of distribution data, forming an optical test solution compliant with mainstream international standards and applicable to R&D and certification scenarios.

Tags: ,

Leave a Message

Your email address will not be published. Required fields are marked *

=