Abstract: Within the EMC surge immunity test framework, the coupling decoupling network (CDN) is an essential accessory installed between the surge generator and the equipment under test. CDNs are mainly divided into two categories according to the port type they match: power line CDNs and Coupling Decoupling Network for Communication Lines. Power line CDNs are designed for AC and DC power supply circuits, while the Coupling Decoupling Network for Communication Lines is dedicated to surge immunity testing on communication, control and signal cables. The Coupling Decoupling Network for Communication Lines is developed to meet the characteristics of immunity tests for the combination wave 1.2/50μs and the communication wave 10/700μs surge waveforms, fully complying with IEC 61000‑4‑5, EN 61000‑4‑5, GB/T 17626.5, ITU‑T K.45, ITU‑T K.21 and ITU‑T K.20. This paper takes the LISUN CDN61000‑5C Coupling Decoupling Network for Communication Lines as the research object. It describes the internal operating mechanism of the Coupling Decoupling Network for Communication Lines, compares the differences in circuit topology, bandwidth, coupling modes and applicable interfaces between power line CDNs and Coupling Decoupling Network for Communication Lines, introduces system configuration when paired with the SG61000‑5 series surge generator, and explains the selection logic of different sub-models. It provides references for laboratories conducting signal-line surge immunity testing, instrument selection and standardized test implementation.
A coupling decoupling network mainly consists of a coupling unit and a decoupling unit. The coupling unit injects high-voltage pulses output by the surge generator onto the conductors of the cable under test. The decoupling unit isolates the auxiliary equipment (AE) side through a high-impedance choke circuit. It prevents the surge high voltage from damaging the downstream auxiliary equipment and also blocks stray signals from the auxiliary equipment from interfering with the test of the equipment under test (EUT). Although power line CDNs and Coupling Decoupling Network for Communication Lines share the same basic function, their internal circuit designs differ greatly due to the different transmission media of the cables under test. Power line CDNs process AC/DC power supply lines, which transmit electric energy without carrying high-speed differential signals and have no constraints on signal bandwidth. The Coupling Decoupling Network for Communication Lines must simultaneously support surge pulse injection and normal transmission of service signals. It must not cause communication signal interruption or distortion when applying surge interference, which constitutes the core design challenge for communication CDNs.
The LISUN CDN61000‑5C Coupling Decoupling Network for Communication Lines can cooperate with the LISUN SG61000‑5 series surge generator to perform tests on various communication lines, control lines and signal lines. This series supports the combination wave 1.2/50μs and the communication-specific 10/700μs surge waveform, which simulate switching overvoltage on power grids and transient high voltage induced by lightning strikes on communication lines respectively. The series includes high-speed, medium-speed and low-speed subfamilies for gigabit Ethernet, CAN, RS485, RS232, LIN and other differential buses of different rates. Common-mode coupling is supported, and some models are also compatible with differential-mode coupling, covering both unbalanced and balanced cables.
The first distinction lies in application targets. Power line CDNs are used for single-phase, three-phase AC or DC power supply ports. They only focus on power delivery without the requirement to preserve high-speed signals. The Coupling Decoupling Network for Communication Lines is applied to signal interfaces such as Ethernet, field buses and serial ports. It must keep the communication link working normally during testing and avoid packet loss or communication failure introduced by parasitic capacitance and inductance of the CDN. The second difference is coupling modes. Most power line CDNs mainly adopt common-mode coupling. According to standard requirements, some Coupling Decoupling Network for Communication Lines support only common-mode coupling, while others can implement both common-mode and differential-mode surge injection to meet the requirements for communication ports specified in ITU‑T telecommunication standards.
Bandwidth constraint is another critical difference. Power line CDNs have no signal bandwidth limitations. The Coupling Decoupling Network for Communication Lines must control its parasitic parameters, and each model has a clear upper limit for data transmission rate. High-speed versions support up to 1000MB/s gigabit Ethernet, medium-speed versions up to 10MB/s, and low-speed versions are only suitable for low-speed buses below 100kB/s. If a low-speed Coupling Decoupling Network for Communication Lines is mistakenly used for a high-speed communication port, the parasitic components will filter the differential signal, directly causing communication failure of the EUT and invalidating the test. There is also a difference in supported surge waveforms. Power line CDNs are mainly designed for the 1.2/50μs combination wave. Besides 1.2/50μs, the Coupling Decoupling Network for Communication Lines must support the 10/700μs surge waveform unique to the telecommunication industry.
The LISUN CDN61000‑5C Coupling Decoupling Network for Communication Lines contains multiple subdivided models. In the model code, H, M and L represent high-speed, medium-speed and low-speed respectively. The number indicates channel quantity, and suffix letters stand for supported surge waveforms and coupling modes. The H series targets 1000MB/s high-speed Ethernet LAN ports, the M series is designed for industrial medium-speed buses such as CAN, RS485 and 4‑20mA, and the L series is used for LIN and low-speed RS232 control lines with rates not higher than 100kB/s. Some models support only common-mode coupling, while versions with the TK suffix support both differential-mode and common-mode coupling.
A complete test system consists of an SG61000‑5 series surge generator, a Coupling Decoupling Network for Communication Lines, EUT and AE. The high-voltage output of the surge generator connects to the surge input port of the CDN. The EUT port connects to the communication device under test, and the AE port connects to auxiliary equipment that maintains communication traffic. During testing, pulses generated by the surge generator are coupled into signal lines via the Coupling Decoupling Network for Communication Lines, while decoupling chokes protect the downstream auxiliary equipment from surge damage. The SG61000‑5 generator is used for 1.2/50μs combination wave tests. The SG61000‑5C variant surge generator should be selected for 10/700μs communication surge tests. The communication status shall be monitored in real time throughout the test to judge whether the surge immunity performance of the device meets the limit.
| Model | Max. Data Rate | Surge Waveforms | Coupling Mode | Typical DUT Interfaces |
|---|---|---|---|---|
| CDN61000‑5C‑H8CC | ≤1000MB/s | 10/700μs, 5/320μs | Common-mode | Gigabit Ethernet RJ45 |
| CDN61000‑5C‑H8BC | ≤1000MB/s | 1.2/50μs, 8/20μs | Common-mode | Gigabit Ethernet RJ45 |
| CDN61000‑5C‑M8TK | ≤10MB/s | 1.2/50μs, 8/20μs, 10/700μs, 5/320μs | Common + Differential mode | CAN, RS485, RS422 |
| CDN61000‑5C‑M4CC | ≤10MB/s | 10/700μs, 5/320μs | Common-mode | RS232, 4‑20mA |
| CDN61000‑5C‑L4BK | ≤100kB/s | 1.2/50μs, 8/20μs, 10/700μs, 5/320μs | Common + Differential mode | LIN, low-speed RS232 |
A large number of industrial gateways, security devices, network switches, smart meters and automotive electronics are equipped with communication and control interfaces. According to IEC 61000‑4‑5 and ITU‑T K series standards, these signal and communication ports must complete surge immunity verification. Power line CDNs cannot replace the Coupling Decoupling Network for Communication Lines for signal line testing. Improper replacement will directly interrupt the communication link, fail to meet standard test conditions and result in test reports unaccepted by certification bodies.
When selecting equipment, users shall first confirm the communication rate of the tested interface, then determine the required surge waveform and whether differential coupling capability is needed. High-speed Ethernet ports must use the H series instead of M or L low-speed versions. Before tests, the Coupling Decoupling Network for Communication Lines shall be within valid calibration period, and the calibration certificate shall provide key indicators such as waveform and coupling attenuation. Cable layout and grounding conditions must strictly follow GB/T 17626.5. During the whole test, testers shall not only observe whether hardware damage occurs on the EUT, but also continuously monitor communication packets and packet loss rate to evaluate whether service functions remain normal under surge interference. The LISUN CDN61000‑5C Coupling Decoupling Network for Communication Lines covers various communication interfaces of industrial and telecommunication equipment. When used together with the SG61000‑5 surge generator, it meets the requirements for R&D pre-compliance testing and third-party type tests, providing hardware support for EMC compliance verification of network, industrial control and instrument products.
Tags:CDN61000-5CYour email address will not be published. Required fields are marked *