Pure Sine Wave AC Power Source (High Precision)

Product No: LSP-500VARC

  • Specifications
  • Downloads
  • Applications
  • Standards
  • Installations
  • The LSP-500VARC High Precision Pure Sine Wave AC Power Supply has the characteristics of good output waveforms, low harmonic, high accuracy, integrated source and meter. With output short-circuit, over-current, over-voltage, over-power, over-temperature alarm protection functions. It can communicate with LISUN LSG series goniophotometer, LPCE-2 high precision integrating sphere spectroradiometer system, LSRF-3 Lamp Start, Run-up Time and Flicker Test System and LS2090 LED Power Driver Tester via RS-232/RS-485 interface.

    Model LSP-500VARC LSP-500VARC-Pst LSP-1KVARC LSP-1KVARC-Pst
    Output Voltage/Phase Single phase: 2V-150V/2V-300V
    2-150V Max. Current 4.2A 4.2A 8.4A 8.4A
    2-300V Max. Current 2.1A 2.1A 4.2A 4.2A
    Output  Frequency Range 45.00~65.00Hz
    Frequency Stability ≤0.05%/30min
    Total Harmonic Distortion ≤0.3 % (No load or full load with resistive load)
    Voltage Stability ≤0.1%/30min
    Equivalent Resistance ≤0.1(Zero internal resistance design)
    Power Supply Efficiency >40%
    Load Effect ≤0.1%
    Communication Port RS232/RS485
    Test Parameters Voltage, Current, Power, PF, Frequency
    Voltage Range 55V/220V
    Voltage Resolution 0.1V
    Voltage Accuracy ±(0.4% rdg+0.2%rng+1digital)
    Current Range 0.2A/2A
    Current Resolution 0.001A
    Current Accuracy ±(0.4% rdg+0.2%rng+1digital)
    Power Resolution 0.1W
    Power Accuracy ±(0.4% rdg+0.2%rng+1digital)

    P.S. LSP-500VARC and LSP-1KVARC are the update versions with big LCD screen. The LSP-500VARC-Pst and LSP-1KVARC-Pst are according to IEC TR 61547-1:2020, IEC61000-3-3, IEC 61000-4-15 and IEEE 1453 Pst programmable function. It can work with LISUN LSRF-3 Lamp Start, Run-up Time and Flicker Test System to test Pst LM(I) parameter.

    Standard:
    IEC Technical Report 61547-1 “Equipment for general lighting purposes – EMC immunity requirements – Part 1: Objective light flickermeter and voltage fluctuation immunity test method”
    IEC61000-3-3 “Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16 A per phase and not subject to conditional connection”
    IEC 61000-4-15 “Electromagnetic compatibility (EMC) – Part 4-15: Testing and measurement techniques – Flickermeter – Functional and design specifications”
    IEEE 1453 “IEEE Standard for Measurement and Limits of Voltage Fluctuations and Associated Light Flicker on AC Power Systems”

    Programmable AC Power Signal Output when do Flicker dynamic Pst LM(I) test in IEC TR 61547-1:2020

    Tags: , , ,
  • Calibrate Certificate

  • LEDs and Luminaire Test Solutions

    LISUN's indoor and outdoor LED luminaires and LED fixtures test solutions fully cover key...

  • IS 16102 (Part 1): 2026 is the latest Indian standard specifying safety requirements for self‑ballasted LED lamps used for general lighting services. Compared with the previous 2012 edition, it...
    IEC 60601-1:2005 is a standard that specifies the general requirements for the basic safety and essential performance of medical electrical equipment. It applies to various types of medical...
    International standard IEC 61010-1 specifies safety requirements for a variety of electrical systems, including test and measurement, industrial process control, and laboratory equipment. The purpose...
    IEC 61196-1:2005 specifies requirements for mineral - insulated cables with a rated voltage not exceeding 750 V. It applies to general wiring cables that have copper or copper - alloy sheaths and...
    IEC 61347-1:2024 specifies the general safety requirements for controlgear used with electric light sources, including fluorescent lamps, LED modules, discharge lamps, and other lighting technologies.
    This standard, "CIE S 025/E:2015 Test Method for LED Lamps, LED Luminaires and LED Modules and its supplement", focuses on setting out measurement methods for electrical, photometric, and...
    This standard IS 15885 (Part 2/Sec 13): 2012  specifies the general and safety requirements for d.c. or a.c. supplied electronic controlgear for LED modules for supply voltages up to and including 1...
    IS 2418-1:2018 Indian Standard (Part 1) (Second Revision) was adopted by the Bureau of Indian Standards, after the draft finalized by the Lamps and Related Equipments Sectional Committee had been...
    IS 16106: 2012 Standard was adopted by the Bureau of Indian Standards, after the draft finalized by the Electric Lamps and Their Auxiliaries Sectional Committee had been approved by the...
  • Netherlands – LISUN engineer provide installation and training for LSG-1800A High Precision Rotation Luminaire Goniophotometer and LSRF-3 Lamp Start, Run-up Time and Flicker Test System

    10 Aug, 2024

    This customer is a supplier of railway lamp in Netherlands. The company decided to establish its own lighting test...