  • CH316 Multiway Life Tester | Multi-Channel Luminaire Switch Life Tester is specifically designed for durability testing of on/off switches in lighting products. The system supports 16 independent, simultaneous test channels, with each channel operating autonomously – ensuring no interference between them – while tracking the number of on/off cycles for each individual sample in real time. Samples can be added or replaced at any point during the test process without interrupting the overall operation. This equipment is widely used by quality control departments in lighting manufacturing firms and by third-party testing laboratories to evaluate the durability and reliability of switches in light sources and luminaires.

    Standards:

    Standards No. Standards Name
    IEC 60598-1:2024 Luminaires – Part 1: General requirements and tests
    IEC 60432‑1:2005 Incandescent lamps‑Part 1:Tungsten filament lamps for domestic and similar general lighting purposes
    GB/T 7000.1-2023 灯具 第 1 部分:一般要求与试验
    GB/T 33721-2026 LED 灯具可靠性试验方法

    Specifications:

    Items Specifications
    Number of Simultaneous Test Channels 16 channels, with independent counting for each channel
    Normal Load Current Range 30mA~1,000mA (RMS)
    Maximum Number of Test Cycles 0~1,000,000 times
    Setting Range for on/off Durations Adjustable from 1 second to 99 hours, 59 minutes, and 59 seconds, with a minimum increment of 1 second.
    Data Storage Functionality Test data is automatically saved in the event of a power failure; testing resumes from the point of interruption once power is restored.
    Expiration Reminder Audible and visual alarms for sample failure; a fault in one channel does not affect the operation of the remaining channels.
    Sample Handling Test samples can be added or replaced at any time during the test process.
    View Data The current cycle life count for each sample can be read at any time.
    Tags:
  • Standards

  • Fluorescent Lamp Test Solutions

    For the Fluorescent Lamp design and manufactory, LISUN can supply a full quality control test...

  • The IEC 62612:2013 standard specifies performance requirements for self-ballasted LED lamps intended for general lighting services, operating at supply voltages greater than 50 V. I
  • Austrilia and Indonesia – Installed goniophotometer, integrating sphere, surge generator and electrical safety test

    05 Apr, 2016

    Our engineer went to Austrilia and Indonisia to install instruments and train them this July. The customer from...