LM-79 Moving Detector Goniophotometer (Mirror Type C)
LSG-6000
High Precision Rotation Luminaire Goniophotometer
LSG-1890B
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1890BCCD
Goniophotometer for Automotive and Signal Lamps
LSG-1950
Goniophotometer for Traffic Signal Lamps
LSG-1950S
Compact Goniophotometer
LSG-1200A
Near Field Moving Detector Goniophotometer
LSG-1900B
Select an organization
to browse standards
Product No: LSHF61000-3-2/3
LISUN Harmonics and Flicker Analyzer Test System includes three professionally matched test instruments: LSHF61000-3-2/3 Harmonics and Flicker Analyzer, LSAIF-503 Flicker Impedance Network and LSP-1KVAC-HF Low-Distortion AC Power Source. It is a complete, high-precision, certification-grade single-phase EMC test system that fully complies with IEC 61000-3-2 (GB 17625.1) “Limits for harmonic current emissions” and IEC 61000-3-3 (GB 17625.2) “Limitation of voltage fluctuations and flicker”.
The system employs a high-speed 16-bit AD converter to deliver high-precision, real-time measurement and analysis of key power quality parameters across the full range of AC input characteristics. It supports comprehensive harmonic assessment and automatic limit evaluation for Class A/B/C/D equipment under test (EUT). The system is widely applied to a variety of electrical and electronic products, including household appliances, LED drivers, power adapters, lighting equipment, control modules, EV chargers and other consumer electronic products.

Harmonic Test Settings According to IEC 61000-3-2 and Flicker Test Settings According to IEC 61000-3-3
Test Parameters:
Harmonics Test Parameters (IEC 61000-3-2): Urms, Irms, P, PF, Freq., DF, THDI, THDU, Ipeak, CFI, CFU, I_fund, THC, POHC, Iphs, Iphp, Iphe, Iphpk+, Iphpk−, I60_90pMin, I60_90nMax and 0–50 individual harmonics (harmonic %, current mA, current mA/W). It automatically evaluates harmonic limits, POHC limits, THD limits, phase criteria for IEC Class A/B/C/D equipment and generates Pass/Fail results.
Flicker Test Parameters (IEC 61000-3-3): dt, dc, dmax, Tmax, Pst, Plt. It supports configuration of target voltage/frequency, observation period and period number; monitors voltage steady range, voltage curve, and fluctuation trends; automatically compares against standard limits and generates Pass/Fail results for dt, dc, dmax, Tmax, Pst and Plt.
Specifications:
| Test Instruments | Specifications |
| LSHF61000-3-2/3 Harmonics Analyzer |
Voltage: single phase 1.000V~600.00V (CF=1.67). Accuracy: ±0.05% of range ±0.05% of reading |
| Current: 2.0mA~13.300A (CF=3). Accuracy: ±0.05% of range ±0.05% of reading | |
| Frequency: 45Hz~65Hz. Accuracy: ±0.1% of reading | |
| Power Factor: 0.000~+1.000. Accuracy: ±0.005 | |
| Harmonics Analyzer: Class 1 according IEC 61000-3-2 | |
| LSHF61000-3-2/3 Flicker Analyzer |
Flicker meter is according IEC 61000-3-3 |
| Accuracy: better than 5% | |
| LSAIF-503 Flicker Impedance |
line 0.24 Ω + j0.15 Ω, neutral 0.16 Ω + j0.10 Ω and single phase 0.4 Ω |
| According IEC 61000-3-3, Max current 16A | |
| LSP-1KVA-HF Low Distortion AC Power Source |
LSP-500VAC-HF: 500VA/0~300V/2.1A@220V; LSP-1KVAC-HF: 1KVA/0~300V/4.2A@220V |
| LSP-2KVAC-HF: 2KVA/0~300V/8.4A@220V; LSP-3KVAC-HF: 3KVA/0~300V/12.6A@220V | |
| LSP-5KVAC-HF: 5KVA/0~300V/21A@220V |
LSHF61000-3-2/3 Harmonics and Flicker Analyzer Test Software:

LSHF61000-3-2/3 Harmonic Test

LSHF61000-3-2/3 Voltage Harmonic

LSHF61000-3-2/3 Current Harmonic

LSHF61000-3-2/3 Current Phase Test

LSHF61000-3-2/3 Current THD Test

LSHF61000-3-2/3 Flicker Test
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.

中文简体