Product No: LIS-CS116
The LIS-CS116 High‑Frequency Damped Transient Pulse Generator is specifically designed for military EMC conducted susceptibility testing. It fully complies with the CS116 requirements of standards GJB 151A/B/C and MIL-STD-461E/F/G. It is primarily used to conduct susceptibility tests on interconnect and power cables for aircraft, surface ships, submarines, aerospace systems, and ground-based systems.
Equipped with a built-in resonant oscillation excitation unit, the LIS-CS116 generates damped sinusoidal/cosinusoidal waveforms across multiple frequency bands in accordance with standard parameters. It utilizes precision impedance-matching circuitry to optimize signal transmission and control waveform damping factors, ensuring stable and controllable output. By precisely injecting high-frequency transient oscillatory pulses into the cables under test, the generator accurately reproduces the high-frequency transient electromagnetic interference environments encountered by military equipment, fully meeting the requirements for testing the conducted immunity performance of military cables and associated equipment.
Specifications:
| LIS‑CS116 High‑Frequency Damped Transient Pulse Generator | |
| Oscillation Frequency (±10%) | 10 kHz 、100kHz 、1 MHz 、10 MHz、 30 MHz 、100 MHz |
| Maximum Output Current | 10 kHz≥0.1A 、100kHz ≥1A、1 MHz≥10A 、10 MHz≥10A、 30 MHz≥10A 、100 MHz≥3A |
| Output Impedance | 50Ω |
| Damping Factor (Q) | 15±5 |
| Attachments Included | Attenuators: Frequency range DC~3 GHz, N-type connector. High-voltage load: 50 Ω. |
| Repetition Frequency | 0.1~30Hz |
| Decoupling Capacitor | 10uF 1600VDC / 440VAC 3-phase |
| Output Interface | N Type |
| Control System | 10.1-inch Android capacitive touchscreen (Chinese/English) + remote control via PC software |
| Operating Environment | Temperature:10℃~40℃,Humidity:30%~70% |
| Power Supply | AC:100~250V@50Hz/60Hz |
| Overall Dimensions | 4U/19″ Standard chamber |
| Mandatory configurations: | |
| LIS-AN50A | Artificial Mains Network: Test voltage DC 1000V/AC 270V, test current 50A (LIS-AN100A and LIS-AN200A optional), N-type connector, impedance 50μH + 5Ω || 50Ω |
| LIS-BCP310 | Bulk Current Injection probe: frequency range 4 kHz~300 MHz; max attenuation 10 dB; N-type connector |
| LIS-CCF600 | Bulk Current Injection probe fixture: frequency range DC~500 MHz, VSWR 2:1 |
| Optional configurations: | |
| LIS-BCM410S | High-current monitoring probe: frequency range 10 kHz~200 MHz, N-type output terminal.. |
Note: The LISUN model LIS-CS115-CS116 is a device that incorporates both CS115 and CS116 testing functions.

CS116 Measured Waveform Plot