LM-79 Moving Detector Goniophotometer (Mirror Type C)
LSG-6000
High Precision Rotation Luminaire Goniophotometer
LSG-1890B
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1890BCCD
Goniophotometer for Automotive and Signal Lamps
LSG-1950
Goniophotometer for Traffic Signal Lamps
LSG-1950S
VAD Fire Alarm Visual Alert Device Goniophotometer
LSG-1930
Compact Goniophotometer
LSG-1200A
LED Goniophotometer
LSG-1100
Select an organization
to browse standards
Product No: LIS-CS115
The LIS-CS115 Fast Square-Wave Pulse Generator is specifically designed for military EMC conducted susceptibility testing. It fully complies with the CS115 requirements of standards GJB 151A/B/C and MIL-STD-461E/F/G. It is primarily used for conducted susceptibility testing of interconnect and power cables in aircraft, aerospace, and ground systems; it can also be adapted to test equipment and subsystems for surface ships and submarines based on customer requirements.
Equipped with a high-speed internal switch, the LIS-CS115 generates pulse signals with precision according to standard parameters. Through signal shaping, filtering, and optimized impedance matching, it eliminates signal reflections and waveform distortion to output standard pulses characterized by steep edges and stable amplitudes. These pulses are precisely injected into the cable under test, accurately replicating the transient electromagnetic interference environments encountered by military equipment and fully meeting testing requirements for the conducted interference immunity of military cables and associated equipment.
Specifications:
| MIL‑STD‑461 CS115 Fast Square‑Wave Pulse Generator | |
| Output Current | 0.1~5A |
| Rise Time | <2nS |
| Fall Time | <2nS |
| Pulse Width | >30nS |
| Output Impedance | 50Ω |
| Attachments Included | Attenuators: Frequency range DC~3 GHz, N-type connector. High-voltage load: 50 Ω. |
| Repetition Frequency | 0.1~30Hz |
| Decoupling Capacitor | 10uF 1600VDC / 440VAC 3-Phase |
| Output Interface | N Type |
| Control System | 10.1-inch Android capacitive touchscreen (Chinese/English) + remote control via PC software |
| Operating Environment | Temperature:10℃~40℃,Humidity:30%~70% |
| Power Supply | AC:100~250V@50Hz/60Hz |
| Overall Dimensions | 4U/19″ Standard chamber |
| Mandatory configurations: | |
| LIS-AN50A | Artificial Mains Network: Test voltage DC 1000V/AC 270V, test current 50A (LIS-AN100A and LIS-AN200A optional), N-type connector, impedance 50μH + 5Ω || 50Ω |
| LIS-BCP310 | Bulk Current Injection probe: frequency range 4 kHz~300 MHz; max attenuation 10 dB; N-type connector |
| LIS-CCF600 | Bulk Current Injection probe fixture: frequency range DC~500 MHz, VSWR 2:1. |
| Optional configurations: | |
| LIS-BCM410S | High-current monitoring probe: frequency range 10 kHz~200 MHz, N-type connector |
Note: The LISUN model LIS-CS115-CS116 is a device that incorporates both CS115 and CS116 testing functions.