LM-79 Moving Detector Goniophotometer (Mirror Type C)
LSG-6000
High Precision Rotation Luminaire Goniophotometer
LSG-1890B
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1890BCCD
Goniophotometer for Automotive and Signal Lamps
LSG-1950
Goniophotometer for Traffic Signal Lamps
LSG-1950S
Compact Goniophotometer
LSG-1200A
Near Field Moving Detector Goniophotometer
LSG-1900B
Select an organization
to browse standards
Whether the device produces steady luminous intensity (category R, R1,RM1, S1 or S3) or variable luminous intensity (category R2, RM2, S2 or
S4).”
In the case of devices of categories R2, RM2, S2 and S4 the time that elapses between energising the light source(s) and the light output measured on the reference axis to reach 90 per cent of the value measured in accordance with paragraph 6.3. above shall be measured for the extreme levels of luminous intensity produced by the device. The time measured to obtain the lowest luminous intensity shall not exceed the time measured to obtain the highest luminous intensity.”
In the case of devices of categories R2, RM2, S2 and S4 the time that elapses between energising the light source(s) and the light output measured on the reference axis to reach 90 per cent of the value measured in accordance with paragraph 6.3. above shall be measured for the extreme levels of luminous intensity produced by the device. The time measured to obtain the lowest luminous intensity shall not exceed the time measured to obtain the highest luminous intensity.’
The colour of the light emitted inside the field of the light distribution grid defined in paragraph 2 of Annex 4 shall be red or white. For testing see Annex 5 to this Regulation. Outside this field, no sharp variation of colour shall be observed.
These requirements shall also apply within the range of variable luminous intensity produced by:
(a) Rear position lamps of category R2;
(b) Rear end-outline marker lamps of category RM2;
(c) Stop lamps of categories S2 and S4.”
LISUN following instruments fully meet ECE R.7 Uniform provisions concerning the approval of front and rear positionlamps, stop-lamps and end-outline marker lamps for motor vehicles(except motor cycles) and their trailers:
LISUN’s automotive electronics test solutions cover photometric/colorimetric testing, EMC immunity tests, IP waterproof/dustproof tests, and environmental simulation, meeting ISO, SAE, ECE standards.
LISUN’s indoor and outdoor LED test solutions meet IEC 60598-1, IEC 62722-2-1, CIE 121 standards, covering safety, photometry, and environmental tests for global compliance.
Introduction In the transportation industry, the measurement of lighting equipment plays a crucial role in ensuring the safety and efficiency of both ground and airborne transportation....
LSG-1950 is a CIE A-α goiophotometer. The photometer head keeps static and it faces to the sample under test while the sample is rotating around both...
LSG-1950S is a high accuracy automatic test system for luminous intensity distribution of traffic signal luminaires and it can be applied to quality evaluation and quality...
The goniophotometer is an instrument that uses spectrophotometry to perform quantitative and qualitative analysis of substances. It is mainly used for the measurement of the light...
With the rapid development of the automobile industry and the improvement of driving speed, it is very necessary to establish various standards and regulations to regulate...
In optical testing, the measurement of luminous flux and color temperature are essential. There are two test equipment for the measurement: Integrating Sphere Testing System and Goniophotometer. Here we...
There is a wide range of goniophotometers on sale in the market, including central rotation type, rotation mirror type, double mirror type and so on. How to choose...
The most critical factor that affects the quality of lighting is the luminous distribution performance of lamps. Using scientific testing methods and selecting the appropriate test...
According to IESNA-LM-79 standard, Goniophotometer is used for light intensity distribution and flux test. Accordingly, Lisun Group is goniophotometer manufacture introduced several different types Goniophotometer, the...
LED automotive light adopts LED (light emitting diode) as a light source. Since the LED possesses advantages of high brightness, variety of colors, low power consumption...

中文简体