Product No: GNGPL-TIS166FA1-2P

  • Specifications
  • LISUN TIS166-2549 Fig A.1 Test Gauge strictly follows Appendix A Clause 9.101 of Thai standard TIS 166-2549. This gauge is designed to verify that single-pole insertion cannot happen on Thai standard socket-outlets. It checks whether a single pin can independently contact the internal contact tube of socket outlets to avoid electric shock risks caused by partial plug insertion. The gauge is manufactured from anti-corrosion stainless steel with sufficient mechanical strength and fixed weight of 200±5 g, which is a mandatory test fixture for TIS safety certification of Thai socket-outlets.

    Specifications:

    LISUN Models GNGPL-TIS166FA1-2P GNGPL-TIS166FA1-3P
    Specifications Used for Two-plug test Used for Three-plug test

    • Standard Reference: TIS 166-2549 Appendix A, Figure A.1, Clause 9.101
    • Material: Stainless steel (non-corrosive metal)
    • Total Mass: 200 ± 5 g
    • Dimensions: Fully comply with millimetre drawing tolerances specified in Figure A.1
    • Supporting Instrument: Electrical indicator, test voltage: 40 V ~ 50 V
    • Function: Verify prevention against single-pole insertion of plugs into socket-outlets

    Test Procedures:
    • Fix the socket-outlet sample, place its mating surface on a horizontal plane with socket openings facing upwards.
    • Apply the TIS166-2549 Fig A.1 gauge in all possible accessible positions and angles to the socket openings.
    • Connect a 40 V to 50 V electrical indicator between the gauge and socket internal conductive components for contact detection.
    • Acceptance requirement: It must NOT be possible for a single gauge pin alone to touch any internal contact tube of the socket-outlet. If single-pole contact occurs, the sample fails the test.
    • Complete the test for all socket positions on the test sample.

    Applications
    • Pre-certification testing for socket-outlets applying for Thailand TIS 166-2549 certification
    • Incoming and production quality inspection for Thai standard wall sockets
    • R&D performance verification for new socket-outlet designs
    • Electrical safety testing laboratories
    • Compliance testing to eliminate electric shock hazards from single-pole insertion