+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
Development of OLED Equipment Manufacturing Technology
05 Jul, 2013 2221 Author: root

Development of OLED Equipment Manufacturing Technology

OLED (Organic Light Emitting Display) is a new generation of flat panel display technology after LCD, LED, CRT and PDP (Plasma Display Panel). It has significant new industry characteristics. OLED is a new type of pure solid (CRT and PDP), which is a new type of pure solid (and LCD) with advantages of LCD and CRT. Besides, OLED has advantages of self luminous (no back light source), simple struct...

Read More
IEC 61000-4-5: Surge Test and Measurement Techniques
05 Jul, 2013 5403 Author: root

IEC 61000-4-5: Surge Test and Measurement Techniques

Surge generator anti-interference measurement is based on the international standard IEC 61000-4-5. SG61000-5_Surge Generator 1 Test objective The entire lightning stroke in the nature (namely the indirect thunder such as the lighting stroke between the clouds, or the lighting stroke happened to the adjacent objects) can induce the surge voltage and current in outdoor aerial. Besides, huge surge ...

Read More
Improve the accuracy of the LED flux testing in the Sphere
07 May, 2013 3552 Author: root

Improve the accuracy of the LED flux testing in the Sphere

Abstract: According to the particularity of LED luminous flux measurement, unique optimization is adopted in the design of the integrating sphere for LED measurement combined with the diffuse materials of high reflectivity, which makes the system stability and accuracy have great improvement. The experimental results show that the system stability and consistency is much higher than other commo...

Read More
Goniophotometer Dark Room Design
17 Mar, 2013 3037 Author: root

Goniophotometer Dark Room Design

Goniophotometer is mainly used for measuring photometric characteristics of luminaries and light source; that is luminaries laser photometric and colorimetric value distribution in different spatial directions. Goniophotometer should be placed to do test in dark room. Many customers concern the size of goniophotometer. According to Energy Star IESNA-LM-79 Clause 10, For measurement of luminous int...

Read More
What’s meaning of Class L and Class A for Photo Detector?
03 Feb, 2013 4482 Author: root

What’s meaning of Class L and Class A for Photo Detector?

LISUN can provide very fine Photo Detectors. They are NIM traceable (directly compared with NIM standard head) and is validated to PTB of Germany. Photo Detector Problem of the part filtering technology: the tested light on the photo detector must be strictly uniform, otherwise even for a so called f1’=0.5% photo detector, its actual f1’ may exceed 10%. Full-filtering technology: in order to a...

Read More
LED Junction Temperature Measurement|Thermal Performance Test for LED
02 Jan, 2013 2639 Author: root

LED Junction Temperature Measurement|Thermal Performance Test for LED

At present, LED and LED lamps and lanterns can’t achieve ideal service life due to the reason of the performance of LED. The LED junction temperature in the working status is not only the direct key to its life and efficacy, but is also influenced by the thermal resistance under the same service conditions. The feasibility of the heat conduction system design of LED also directly affects the li...

Read More
Spectrophotometer and Colorimeter
21 Nov, 2012 3194 Author: root

Spectrophotometer and Colorimeter

When choosing the instrument to purchase or use for the application, it is very important to understand the types of instruments available for measuring color. A colorimeter or spectrophotometer can be used to measure any test substance that is itself colored or can be reacted to produce a color. Both colorimeter and spectrophotometer provide data obtained over the same range of visible wavele...

Read More
CIE Lighting Body and Standard Illuminant
07 Sep, 2012 2831 Author: root

CIE Lighting Body and Standard Illuminant

When you measure the photometric and chromaticity properties of optical system, it must be under the uniformly prescribed light source, the test result can be compared with each other. In order to unite the measurement standards, the International Commission on Illumination (CIE) provides the lighting body and standard illuminant. The definition of “illuminant” and “lighting body” by CIE s...

Read More
IESNA-LM-79-08 Test Solution: Goniophotometer
27 Jun, 2012 3162 Author: root

IESNA-LM-79-08 Test Solution: Goniophotometer

The U.S. Government issued her LED test standards IESNA-LM-79-08. This approved method is a guide developed for the measurement of Solid State Lighting (SSL) products such as LED Street Light, LED Flood Light, LED Down Light, LED Ceiling Light, LED Par Light, LED Tube, LED Module and so on. The most of LED fixtures manufactory use the Integrating Sphere to do the color and photo parameters ...

Read More