Product No: LFCI61000-19
The LFCI61000-19 Low-Frequency Differential-Mode Conducted Immunity Test System incorporates a signal source, power amplifier, and single-phase coupling/decoupling network. It is used to apply differential-mode conducted interference within the DC~180kHz frequency range to AC power ports, evaluating the immunity performance of electrical and electronic equipment to low-frequency differential-mode interference. It simulates on-site electromagnetic environments such as power grid switching disturbances, carrier communication, and differential-mode voltage and current disturbances at power ports caused by the operation of power electronic equipment. It is widely used for EMC type testing of products such as electricity meters, industrial control equipment, relays, power electronic devices, and instruments, as well as in third-party testing laboratories and enterprise R&D and quality control departments.
Standards:
| Standards No | Standards Name |
| IEC 61000‑4‑19:2014 | Electromagnetic compatibility (EMC) – Part 4‑19: Testing and measurement techniques‑Test for immunity to conducted, differential‑mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports |
| GB/T 17626.19‑2022 | 电磁兼容 试验和测量技术 第 19 部分:交流电源端口 2 kHz~150 kHz 差模传导骚扰和通信信号抗扰度试验 |
Specifications:
| Differential Mode Voltage Test Parameters according to IEC 61000‑4‑19 table 1 | |
| Frequency Range | 2kHz~180kHz |
| Open Circuit Voltage | 0.1V ~ 30V ±5% |
| Harmonic Distortion | <5%(sine wave) |
| Pulse Modulation | 3Hz~1kHz |
| Output Impedance | 10 Ω±30% |
| Differential Mode Current Test Parameters according to IEC 61000‑4‑19 table 2 | |
| Frequency Range | 2 kHz~180 kHz |
| Current | 6 A |
| Load Output Impedance | 1Ω±0.3 Ω |
| Overall Parameters | |
| Pulse Modulation Duty Cycle | 0.5 |
| DUT Voltage and Current | Built-in coupling/decoupling network: Single phase 240V/16A |
| Control System | 10.1-inch Chinese/English Android capacitive touchscreen display + supports remote control via PC software |
| Output Interface | LAN、USB、RS485 |
| Usage Environment | Temperature :10~40℃ , Humidity :30%~70% |
| Working Power Supply | AC:110~250V/10A 50Hz/60Hz |