Rotation Luminaire Goniospectroradiometer

Rotation Luminaire Goniospectroradiometer

Product No: LSG-1800CCD

  • Description
  • Video
  • Download
  • Inquiry

LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.

 

Specification:
• Meets the requirements of CIE, IEC, IES LM-79 & GB standards
• Reaching many measurement ways such as B-Beta & C-Gamma (LSG-1800CCD) and C-Gamma (LSG-1700CCD)
• The tested luminaries rotates around an angle of (γ)±180°(or 0-360°) and the tested luminaries rotates around itself with an angle of (C)±180°(or 0-360°)
• Luminosity Testing Range: Illuminance 0.001lx~10,000lx; Light Intensity 1.0cd~107cd(detector)
• The accuracy of angle: 0.2°
• Test CCT and Spectrum Distribution Test for the lamp, the data can be export be excel
• Spectral Range Wavelength: 380~780nm; Wavelength Accuracy: ±0.2nm
• Accuracy of Chromaticity Coordinates x, y: ±0.0015
• Correlated Color Temperature Range: 1000~100000K, Resolution: 1K
• Accuracy of photometry: Class 1
• Testing Accuracy: 3%(Under Standard lamp); Stray Light: less than 0.2%
• English version software can run in Win 7, Win8 or Win 10

Max Size for the Testing Lamp (mm)The max size for the Testing LampMax Weight
C-Gamma Test with one PillarB-Beta Test with Two Pillars
LSG-1800CCD1600*550700*60050kg
LSG-1700CCD1600*550N/A40kg

 

Related Technical Articles
1. The difference between Integrating Sphere Test System and Goniophotometer
2. Darkroom Design of goniophotometer
3. Similarities and Differences between Photometric Measurements of Goniophotometer and Integrating Sphere for Solid State Lighting Products
4. Advantages and disadvantages for total flux test of Integrating Sphere System and Goniophotometer
5. Goniophotometer System Standard Operating Procedures
6. How to choose the right goniophotometer according to the standard LM-79 and EN13032-1?
7. How to choose Goniophotometer
8. LISUN engineer visit Croatia to install and train goniophotometer.
9. According to IESNA-LM-79, How to Choose the Integrating Sphere and Goniophotometer
10. Characteristics and Applications of Different Type Goniophotometer
11. Types & Test Methods of Luminaires Goniophotometer
12. Lumen test difference between integrating sphere and goniophotometer
13. Maintenance of Goniophotometer and Integrating Sphere
14. How To Build The Darkroom For Goniophotometer?
15. Goniophotometer Dark Room Design
16. IESNA-LM-79-08 Test Solution: Goniophotometer