Lisun Electronics Inc.
Tel: +86(21)5108 3341
Fax: +86(21)5108 3342
Email: Sales@Lisungroup.com
[Global Office information......]
Specification:
• It according to IEC60695-2-10~IEC60695-2-13(GB/T5169.10-2006~GB/T5169.13-2006),《basic testing methods of Glow wire, basic testing methods of Glow wire device》and UL 746A, IEC829, DIN695, VDE0471; Glow wire diameter: 4mm±0.04mm Ni/Cr(80/20)special-ordered standard ring shape, put in horizontal;
• Thermocouple diameter: 0.5mm K type, import insulated thermocouple which can endure high temperature, and it can endure about 1100 ℃ (superior to standard 1050 ℃);
• Glow wire heating temperature under electrified: 500 ℃~960 ℃ (digital display, can be preset), fluctuation of temperature < 3 ℃;
• Inspect the temperature during the test: thermocouple is located between Glow wire tester and back panel of box, with distance of 100 m. The outer connect to a temperature to display temperature;
• Test height of flame: Ruler of flame height;
• The press of Glow wire: 1.0N±0.1N(adjustable )(superior to standard 1.0N±0.2N);
• The maximum depth of insertion: 7mm ± 0.5mm ( adjustable ) the maximum depth of insertion;
• Mobile speed of the tested goods: 10mm /s~25mm /s;
• Test time: 30s±0.1s(1s~999.9s digital display, can be preset);
• Thickness of matting used to ignite: Thickness: 10mm; deal board cover 12g /m 2~30g /mm 2 standard paper, above the glow wire about 200mm ± 5mm
• Test space: 0.5m 3,with black background, illuminance of background≤ 20Lux, the material of box is stainless steel;
• Power: 1kVA 220V 50-60Hz
Products of this category:
ZRS-3H: The glow wire test apparatus is according to IEC60695-2-10~IEC60695-2-13(GB/T5169.10-2006~GB/T5169.13-2006), UL 746A, IEC829, DIN695, VDE0471.
ZY-3: Needle Flame Test. This electrical safety tester is fit for the industry of insulation material, engineering plastics and solid combustible material.
TTC-1: Tracking Test Chamber. Test insulation material according to IEC 60112-2003, etc.
TMP-L: Temperature Meter for Lamp Caps & Luminaries Test. This temperature chamber is used to test the working and environmental temperature of burner and lamp.
LS9934-1KVA: Automatic Safety Test System. Withstanding voltage, insulation resistance, grounding resistance and leakage current test.
LS9922I: Programmable withstand voltage and insulation test.
WB2671A: AC and DC withstand voltage test. Output voltage: 0-5kV.
WB2681A: Insulation resistance. Insulation test voltages: DC250V、DC500V、DC1000V.
JC2202TA: Digital Oscilloscope. Contact us for more about electrical safety testing.