Method 2005: Peak Emission Wavelength, Spectral Radiation Bandwidth and Spectrum Power Distribution
1 Objective
Measure the peak emission wavelength, spectral radiation bandwidth and spectrum power distribution of the measuring LED device under the rated condition.
2 Test chart

Picture 11 method 2005 test chart
D:The measuring LED device
G:Current source
L:Focus lens system
G:Current source (dc or pulse)
D2,D3:Eliminate stray light diaphragm;
M:Monochromator
RM:Radiation detection system including diaphragm D1
Note: the wavelength resolution and bandwidth of the monochromator should make the test have suitable precision. The spectral response of the radiation detection system should be calibrated. For convenience of measurement, the curve peak can be expressed by using 100%. If the spectrum through rate of the monochromator and the spectrum sensitivity of the radiation detection system are not constant, the recording measurement data should be revised.
3 Test procedure
Within the scope of the spectrum needed, adjust the wavelength of the monochromator to make the radiation measuring system get to the maximum readout, the corresponding wavelength is the peak wavelength (λ p), and then adjust the monochromator peak wavelength of the λ p to half the readout value of the peak wavelength to obtain the corresponding wavelength λ 1 and λ 2, the difference of them is the spectral radiant bandwidth. According to the requirements of the wavelength interval, measure and record the spectrum power value of each wavelength that is namely the spectrum power distribution.

Picture 12 Spectral distribution bandwidth
4 Rated condition
Environment and tube temperature
Rated forward current (DC or pulse)
About Lisun Group:
Lead in CFL and LED Tester. Click to our product lists:
Goniophotometer
Spektrofotometer
Integrating Sphere
Colorimeter
Photometer
LED Test Instruments
CFL Test instruments
EMC testing
Electronic Ballast Tester
Equipments for Testing Electronic components
Electrical Safety Tester
Environmental testing equipment
AC and DC power supply
Spectrophotometer
Related posts:
- LEDs Test Method: Radiation Flux and Radiation Efficiency
- Basic Theories About Goniophotometer Part3: Spatial Luminance Distribution and Spatial Spectral Distribution
- LEDs Test Method: Light Characteristics Measuring Methods
- Lisun LED Test Solution and Measuring Method Part1: Electrical and Optical Characteristics
- LEDs Test Method: The Electrical Characteristics Testing Methods
- Distributive Radiation Method for Measuring Ultraviolet Radiation Flux
- LEDs Test Method: Luminous Flux and Luminous Efficiency
- Semiconductor LEDs Test Method
- Maximum Rating and General Requirements of LEDs Test
- LED Quality Evaluation